The 16 registers of TSENS (Temperature Sensor), from 0x40003000, with their reset value and every field. The ATSAMC21J18A has 1372 registers in 47 peripherals, one page each.
TSENS Temperature Sensor
CTRLAControl A Register
Address
0x40003000
Reset
0x00
Access
read/write
7–
6RUNSTDBY
5–
4–
3–
2–
1ENABLE
0SWRST
3 fields
Field
Bits
What it does
RUNSTDBY
6
Run in Standby
ENABLE
1
Enable
SWRST
0
Software Reset
CTRLBControl B Register
Address
0x40003001
Reset
0x00
Access
write only
7–
6–
5–
4–
3–
2–
1–
0START
1 field
Field
Bits
What it does
START
0
Start Measurement
CTRLCControl C Register
Address
0x40003002
Reset
0x00
Access
read/write
7–
6–
5–
4FREERUN
3–
2WINMODE2
1WINMODE1
0WINMODE0
2 fields
Field
Bits
What it does
FREERUN
4
Free Running Measurement
WINMODE
2:0
Window Monitor Mode
0 No window mode (default)
1 VALUE greater than WINLT
2 VALUE less than WINUT
3 VALUE greater than WINLT and VALUE less than WINUT
4 VALUE less than WINLT or VALUE greater than WINUT
5 VALUE greater than WINUT with hysteresis to WINLT