AVR32EA28 DAC0 registers The 2 registers of DAC0 (Digital to Analog Converter), from 0x6A0, with their reset value and every field. The AVR32EA28 has 492 registers in 43 peripherals, one page each.
DAC0 Digital to Analog Converter CTRLAControl Register A
Address 0x6A0
Reset 0x00
Access read/write 7 RUNSTDBY 6 OUTEN 5 OUTRANGE1 4 OUTRANGE0 3 – 2 – 1 – 0 ENABLE 4 fields
Field Bits What it does RUNSTDBY 7 Run in Standby Mode OUTEN 6 Output Buffer Enable OUTRANGE 5:4 Output Buffer Range0 Output buffer automatically choose best range2 Output buffer configured to low range3 Output buffer configured to high range ENABLE 0 DAC Enable
DATADATA Register
Address 0x6A2
Reset 0x0000
Access read/write
Size 16-bit 1 field
Field Bits What it does DATA 15:6 Data