The 8 registers of SWDT (Synchronous Watchdog Timer), from 0xE20, with their reset value and every field. The AVR32SD20 has 580 registers in 51 peripherals, one page each.
SWDT Synchronous Watchdog Timer
CTRLAControl A
Address
0xE20
Reset
0x00
Access
read/write
7–
6–
5–
4–
3CCP
2LOCK
1MODE
0ENABLE
4 fields
Field
Bits
What it does
CCP
3
SWDT Register Lock
LOCK
2
Register Lock
0 SWDT SFRs are not LOCK-Protected
1 SWDT SFRs are LOCK-Protected
MODE
1
Peripheral Mode
0 SWDT counts clock cycles
1 SWDT counts executed instructions
ENABLE
0
Peripheral Enable
CTRLBControl B
Address
0xE21
Reset
0x00
Access
write only
7–
6–
5–
4–
3–
2–
1–
0TEST
1 field
Field
Bits
What it does
TEST
0
Test
INTCTRLInterrupt Control
Address
0xE22
Reset
0x00
Access
read/write
7–
6–
5–
4–
3ERROR
2–
1–
0–
1 field
Field
Bits
What it does
ERROR
3
SWDT Error interrupt enable
INTFLAGSInterrupt Flags
Address
0xE23
Reset
0x00
Access
read/write
7BADPC
6BADC
5UC
4EXP
3ERROR
2–
1PRECLEAR
0CLEAR
7 fields
Field
Bits
What it does
BADPC
7
Non-PRECLEAR Command received while expecting PRECLEAR