The 6 registers of AC1 (Analog Comparator), from 0x688, with their reset value and every field. The AVR64DB64 has 745 registers in 62 peripherals, one page each.
AC1 Analog Comparator
CTRLAControl A
Address
0x688
Reset
0x00
Access
read/write
7RUNSTDBY
6OUTEN
5–
4POWER1
3POWER0
2HYSMODE1
1HYSMODE0
0ENABLE
5 fields
Field
Bits
What it does
RUNSTDBY
7
Run in Standby Mode
OUTEN
6
Output Pad Enable
POWER
4:3
Power profile
0 Power profile 0, Shortest response time, highest consumption
1 Power profile 1
2 Power profile 2
HYSMODE
2:1
Hysteresis Mode
0 No hysteresis
1 Small hysteresis
2 Medium hysteresis
3 Large hysteresis
ENABLE
0
Enable
CTRLBControl B
Address
0x689
Reset
0x00
Access
read/write
7–
6–
5–
4–
3–
2–
1WINSEL1
0WINSEL0
1 field
Field
Bits
What it does
WINSEL
1:0
Window selection mode
0 Window function disabled
1 Select ACn+1 as upper limit in window compare
2 Select ACn+2 as upper limit in window compare
MUXCTRLMux Control A
Address
0x68A
Reset
0x00
Access
read/write
7INVERT
6INITVAL
5MUXPOS2
4MUXPOS1
3MUXPOS0
2MUXNEG2
1MUXNEG1
0MUXNEG0
4 fields
Field
Bits
What it does
INVERT
7
Invert AC Output
INITVAL
6
AC Output Initial Value
0 Output initialized to 0
1 Output initialized to 1
MUXPOS
5:3
Positive Input MUX Selection
0 Positive Pin 0
1 Positive Pin 1
2 Positive Pin 2
3 Positive Pin 3
MUXNEG
2:0
Negative Input MUX Selection
0 Negative Pin 0
1 Negative Pin 1
2 Negative Pin 2
3 DAC Reference
DACREFDAC Voltage Reference
Address
0x68D
Reset
0xFF
Access
read/write
7DACREF7
6DACREF6
5DACREF5
4DACREF4
3DACREF3
2DACREF2
1DACREF1
0DACREF0
1 field
Field
Bits
What it does
DACREF
7:0
DACREF
INTCTRLInterrupt Control
Address
0x68E
Reset
0x00
Access
read/write
7–
6–
5INTMODE1
4INTMODE0
3–
2–
1–
0CMP
3 fields
Field
Bits
What it does
INTMODE
5:4
Interrupt Mode
0 Positive and negative inputs crosses
2 Positive input goes below negative input
3 Positive input goes above negative input
INTMODE
5:4
Interrupt Mode
0 Window interrupt when input above both references
1 Window interrupt when input betweeen references
2 Window interrupt when input below both references