PIC16F18877 SMT1 registers

The 18 registers of SMT1 (Signal measurement timer 1), from 0x48C, with their reset value and every field. The PIC16F18877 has 474 registers in 46 peripherals, one page each.

SMT1 Signal measurement timer 1

SMT1TMRL

Address
0x48C
Reset
0x00
Access
read/write
  1. 7TMR7
  2. 6TMR6
  3. 5TMR5
  4. 4TMR4
  5. 3TMR3
  6. 2TMR2
  7. 1TMR1
  8. 0TMR0
1 field
FieldBitsWhat it does
TMR7:0

SMT1TMRH

Address
0x48D
Reset
0x00
Access
read/write
  1. 7TMR7
  2. 6TMR6
  3. 5TMR5
  4. 4TMR4
  5. 3TMR3
  6. 2TMR2
  7. 1TMR1
  8. 0TMR0
1 field
FieldBitsWhat it does
TMR7:0

SMT1TMRU

Address
0x48E
Reset
0x00
Access
read/write
  1. 7TMR7
  2. 6TMR6
  3. 5TMR5
  4. 4TMR4
  5. 3TMR3
  6. 2TMR2
  7. 1TMR1
  8. 0TMR0
1 field
FieldBitsWhat it does
TMR7:0

SMT1CPRL

Address
0x48F
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPR7
  2. 6CPR6
  3. 5CPR5
  4. 4CPR4
  5. 3CPR3
  6. 2CPR2
  7. 1CPR1
  8. 0CPR0
1 field
FieldBitsWhat it does
CPR7:0

SMT1CPRH

Address
0x490
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPR7
  2. 6CPR6
  3. 5CPR5
  4. 4CPR4
  5. 3CPR3
  6. 2CPR2
  7. 1CPR1
  8. 0CPR0
1 field
FieldBitsWhat it does
CPR7:0

SMT1CPRU

Address
0x491
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPR7
  2. 6CPR6
  3. 5CPR5
  4. 4CPR4
  5. 3CPR3
  6. 2CPR2
  7. 1CPR1
  8. 0CPR0
1 field
FieldBitsWhat it does
CPR7:0

SMT1CPWL

Address
0x492
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPW7
  2. 6CPW6
  3. 5CPW5
  4. 4CPW4
  5. 3CPW3
  6. 2CPW2
  7. 1CPW1
  8. 0CPW0
1 field
FieldBitsWhat it does
CPW7:0

SMT1CPWH

Address
0x493
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPW7
  2. 6CPW6
  3. 5CPW5
  4. 4CPW4
  5. 3CPW3
  6. 2CPW2
  7. 1CPW1
  8. 0CPW0
1 field
FieldBitsWhat it does
CPW7:0

SMT1CPWU

Address
0x494
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPW7
  2. 6CPW6
  3. 5CPW5
  4. 4CPW4
  5. 3CPW3
  6. 2CPW2
  7. 1CPW1
  8. 0CPW0
1 field
FieldBitsWhat it does
CPW7:0

SMT1PRL

Address
0x495
Reset
0xFF
Access
read/write
  1. 7PR7
  2. 6PR6
  3. 5PR5
  4. 4PR4
  5. 3PR3
  6. 2PR2
  7. 1PR1
  8. 0PR0
1 field
FieldBitsWhat it does
PR7:0

SMT1PRH

Address
0x496
Reset
0xFF
Access
read/write
  1. 7PR7
  2. 6PR6
  3. 5PR5
  4. 4PR4
  5. 3PR3
  6. 2PR2
  7. 1PR1
  8. 0PR0
1 field
FieldBitsWhat it does
PR7:0

SMT1PRU

Address
0x497
Reset
0xFF
Access
read/write
  1. 7PR7
  2. 6PR6
  3. 5PR5
  4. 4PR4
  5. 3PR3
  6. 2PR2
  7. 1PR1
  8. 0PR0
1 field
FieldBitsWhat it does
PR7:0

SMT1CON0

Address
0x498
Reset
0x00
Access
read/write
  1. 7EN
  2. 6–
  3. 5STP
  4. 4WPOL
  5. 3SPOL
  6. 2CPOL
  7. 1PS1
  8. 0PS0
6 fields
FieldBitsWhat it does
EN7
STP5
WPOL4
SPOL3
CPOL2
PS1:0

SMT1CON1

Address
0x499
Reset
0x00
Access
read/write
  1. 7GO
  2. 6REPEAT
  3. 5–
  4. 4–
  5. 3MODE3
  6. 2MODE2
  7. 1MODE1
  8. 0MODE0
3 fields
FieldBitsWhat it does
GO7
REPEAT6
MODE3:0

SMT1STAT

Address
0x49A
Reset
0x00
Access
read/write
  1. 7CPRUP
  2. 6CPWUP
  3. 5RST
  4. 4–
  5. 3–
  6. 2TS
  7. 1WS
  8. 0AS
6 fields
FieldBitsWhat it does
CPRUP7
CPWUP6
RST5
TS2
WS1
AS0

SMT1CLK

Address
0x49B
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4–
  5. 3–
  6. 2CSEL2
  7. 1CSEL1
  8. 0CSEL0
1 field
FieldBitsWhat it does
CSEL2:0

SMT1SIG

Address
0x49C
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4SSEL4
  5. 3SSEL3
  6. 2SSEL2
  7. 1SSEL1
  8. 0SSEL0
1 field
FieldBitsWhat it does
SSEL4:0

SMT1WIN

Address
0x49D
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4WSEL4
  5. 3WSEL3
  6. 2WSEL2
  7. 1WSEL1
  8. 0WSEL0
1 field
FieldBitsWhat it does
WSEL4:0