PIC18F55Q24 NCO1 registers

The 8 registers of NCO1 (Numerically controlled oscillator 1), from 0x440, with their reset value and every field. The PIC18F55Q24 has 683 registers in 50 peripherals, one page each.

NCO1 Numerically controlled oscillator 1

NCO1ACCL

Address
0x440
Reset
0x00
Access
read/write
  1. 7ACC7
  2. 6ACC6
  3. 5ACC5
  4. 4ACC4
  5. 3ACC3
  6. 2ACC2
  7. 1ACC1
  8. 0ACC0
1 field
FieldBitsWhat it does
ACC7:0

NCO1ACCH

Address
0x441
Reset
0x00
Access
read/write
  1. 7ACC7
  2. 6ACC6
  3. 5ACC5
  4. 4ACC4
  5. 3ACC3
  6. 2ACC2
  7. 1ACC1
  8. 0ACC0
1 field
FieldBitsWhat it does
ACC7:0

NCO1ACCU

Address
0x442
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4–
  5. 3ACC3
  6. 2ACC2
  7. 1ACC1
  8. 0ACC0
1 field
FieldBitsWhat it does
ACC3:0

NCO1INCL

Address
0x443
Reset
0x01
Access
read/write
  1. 7INC7
  2. 6INC6
  3. 5INC5
  4. 4INC4
  5. 3INC3
  6. 2INC2
  7. 1INC1
  8. 0INC0
1 field
FieldBitsWhat it does
INC7:0

NCO1INCH

Address
0x444
Reset
0x00
Access
read/write
  1. 7INC7
  2. 6INC6
  3. 5INC5
  4. 4INC4
  5. 3INC3
  6. 2INC2
  7. 1INC1
  8. 0INC0
1 field
FieldBitsWhat it does
INC7:0

NCO1INCU

Address
0x445
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4–
  5. 3INC3
  6. 2INC2
  7. 1INC1
  8. 0INC0
1 field
FieldBitsWhat it does
INC3:0

NCO1CONConfigurable logic cell control

Address
0x446
Reset
0x00
Access
read/write
  1. 7EN
  2. 6–
  3. 5OUT
  4. 4POL
  5. 3–
  6. 2–
  7. 1–
  8. 0PFM
4 fields
FieldBitsWhat it does
EN7
OUT5
POL4
PFM0

NCO1CLK

Address
0x447
Reset
0x00
Access
read/write
  1. 7PWS2
  2. 6PWS1
  3. 5PWS0
  4. 4CKS4
  5. 3CKS3
  6. 2CKS2
  7. 1CKS1
  8. 0CKS0
2 fields
FieldBitsWhat it does
PWS7:5