PIC18LF26K83 SMT2 registers

The 18 registers of SMT2 (Signal measurement timer 2), from 0x3F00, with their reset value and every field. The PIC18LF26K83 has 905 registers in 55 peripherals, one page each.

SMT2 Signal measurement timer 2

SMT2TMRL

Address
0x3F00
Reset
0x00
Access
read/write
  1. 7TMR7
  2. 6TMR6
  3. 5TMR5
  4. 4TMR4
  5. 3TMR3
  6. 2TMR2
  7. 1TMR1
  8. 0TMR0
1 field
FieldBitsWhat it does
TMR7:0

SMT2TMRH

Address
0x3F01
Reset
0x00
Access
read/write
  1. 7TMR7
  2. 6TMR6
  3. 5TMR5
  4. 4TMR4
  5. 3TMR3
  6. 2TMR2
  7. 1TMR1
  8. 0TMR0
1 field
FieldBitsWhat it does
TMR7:0

SMT2TMRU

Address
0x3F02
Reset
0x00
Access
read/write
  1. 7TMR7
  2. 6TMR6
  3. 5TMR5
  4. 4TMR4
  5. 3TMR3
  6. 2TMR2
  7. 1TMR1
  8. 0TMR0
1 field
FieldBitsWhat it does
TMR7:0

SMT2CPRL

Address
0x3F03
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPR7
  2. 6CPR6
  3. 5CPR5
  4. 4CPR4
  5. 3CPR3
  6. 2CPR2
  7. 1CPR1
  8. 0CPR0
1 field
FieldBitsWhat it does
CPR7:0

SMT2CPRH

Address
0x3F04
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPR7
  2. 6CPR6
  3. 5CPR5
  4. 4CPR4
  5. 3CPR3
  6. 2CPR2
  7. 1CPR1
  8. 0CPR0
1 field
FieldBitsWhat it does
CPR7:0

SMT2CPRU

Address
0x3F05
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPR7
  2. 6CPR6
  3. 5CPR5
  4. 4CPR4
  5. 3CPR3
  6. 2CPR2
  7. 1CPR1
  8. 0CPR0
1 field
FieldBitsWhat it does
CPR7:0

SMT2CPWL

Address
0x3F06
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPW7
  2. 6CPW6
  3. 5CPW5
  4. 4CPW4
  5. 3CPW3
  6. 2CPW2
  7. 1CPW1
  8. 0CPW0
1 field
FieldBitsWhat it does
CPW7:0

SMT2CPWH

Address
0x3F07
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPW7
  2. 6CPW6
  3. 5CPW5
  4. 4CPW4
  5. 3CPW3
  6. 2CPW2
  7. 1CPW1
  8. 0CPW0
1 field
FieldBitsWhat it does
CPW7:0

SMT2CPWU

Address
0x3F08
Reset
x (not fixed at power-on)
Access
read only
  1. 7CPW7
  2. 6CPW6
  3. 5CPW5
  4. 4CPW4
  5. 3CPW3
  6. 2CPW2
  7. 1CPW1
  8. 0CPW0
1 field
FieldBitsWhat it does
CPW7:0

SMT2PRL

Address
0x3F09
Reset
0xFF
Access
read/write
  1. 7PR7
  2. 6PR6
  3. 5PR5
  4. 4PR4
  5. 3PR3
  6. 2PR2
  7. 1PR1
  8. 0PR0
1 field
FieldBitsWhat it does
PR7:0

SMT2PRH

Address
0x3F0A
Reset
0xFF
Access
read/write
  1. 7PR7
  2. 6PR6
  3. 5PR5
  4. 4PR4
  5. 3PR3
  6. 2PR2
  7. 1PR1
  8. 0PR0
1 field
FieldBitsWhat it does
PR7:0

SMT2PRU

Address
0x3F0B
Reset
0xFF
Access
read/write
  1. 7PR7
  2. 6PR6
  3. 5PR5
  4. 4PR4
  5. 3PR3
  6. 2PR2
  7. 1PR1
  8. 0PR0
1 field
FieldBitsWhat it does
PR7:0

SMT2CON0

Address
0x3F0C
Reset
0x00
Access
read/write
  1. 7EN
  2. 6–
  3. 5STP
  4. 4WPOL
  5. 3SPOL
  6. 2CPOL
  7. 1PS1
  8. 0PS0
6 fields
FieldBitsWhat it does
EN7
STP5
WPOL4
SPOL3
CPOL2
PS1:0

SMT2CON1

Address
0x3F0D
Reset
0x00
Access
read/write
  1. 7GO
  2. 6REPEAT
  3. 5–
  4. 4–
  5. 3MODE3
  6. 2MODE2
  7. 1MODE1
  8. 0MODE0
3 fields
FieldBitsWhat it does
GO7
REPEAT6
MODE3:0

SMT2STAT

Address
0x3F0E
Reset
0x00
Access
read/write
  1. 7CPRUP
  2. 6CPWUP
  3. 5RST
  4. 4–
  5. 3–
  6. 2TS
  7. 1WS
  8. 0AS
6 fields
FieldBitsWhat it does
CPRUP7
CPWUP6
RST5
TS2
WS1
AS0

SMT2CLK

Address
0x3F0F
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4–
  5. 3–
  6. 2CSEL2
  7. 1CSEL1
  8. 0CSEL0
1 field
FieldBitsWhat it does
CSEL2:0

SMT2SIG

Address
0x3F10
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4SSEL4
  5. 3SSEL3
  6. 2SSEL2
  7. 1SSEL1
  8. 0SSEL0
1 field
FieldBitsWhat it does
SSEL4:0

SMT2WIN

Address
0x3F11
Reset
0x00
Access
read/write
  1. 7–
  2. 6–
  3. 5–
  4. 4WSEL4
  5. 3WSEL3
  6. 2WSEL2
  7. 1WSEL1
  8. 0WSEL0
1 field
FieldBitsWhat it does
WSEL4:0