PIC32CZ1038CA70144 RTT registers

The 4 registers of RTT (Real-time Timer), from 0x400E1830, with their reset value and every field. The PIC32CZ1038CA70144 has 2990 registers in 68 peripherals, one page each.

RTT Real-time Timer

RTT_MRMode Register

Address
0x400E1830
Reset
0x00000000
Access
read/write
Size
32-bit
6 fields
FieldBitsWhat it does
RTC1HZ24Real-Time Clock 1Hz Clock Selection
RTTDIS20Real-time Timer Disable
RTTRST18Real-time Timer Restart
RTTINCIEN17Real-time Timer Increment Interrupt Enable
ALMIEN16Alarm Interrupt Enable
RTPRES15:0Real-time Timer Prescaler Value

RTT_ARAlarm Register

Address
0x400E1834
Reset
0x00000000
Access
read/write
Size
32-bit
1 field
FieldBitsWhat it does
ALMV31:0Alarm Value

RTT_VRValue Register

Address
0x400E1838
Reset
0x00000000
Access
read only
Size
32-bit
1 field
FieldBitsWhat it does
CRTV31:0Current Real-time Value

RTT_SRStatus Register

Address
0x400E183C
Reset
0x00000000
Access
read only
Size
32-bit
2 fields
FieldBitsWhat it does
RTTINC1Prescaler Roll-over Status (cleared on read)
ALMS0Real-time Alarm Status (cleared on read)