The 40 registers of ETM (Embedded Trace Macrocell), from 0xE0041000, with their reset value and every field. The PIC32WM_BZ6602 has 3597 registers in 73 peripherals, one page each.
ETM Embedded Trace Macrocell
CRETM Main Control Register
Address
0xE0041000
Reset
0x00000411
Access
read/write
Size
32-bit
11 fields
Field
Bits
What it does
TSEN
28
TimeStamp Enable
PORTSIZE3
21
Port Size bit 3
PORTMODE
17:16
Port Mode bits 1:0
PORTMODE2
13
Port Mode bit 2
PORTSEL
11
ETM Port Select
PROG
10
ETM Programming
DBGRQ
9
Debug Request Control
BROUT
8
Branch Output
STALL
7
Stall Processor
PORTSIZE
6:4
Port Size bits 2:0
ETMPD
0
ETM Power Down
CCRETM Configuration Code Register
Address
0xE0041004
Reset
0x8C802000
Access
read only
Size
32-bit
TRIGGERETM Trigger Event Register
Address
0xE0041008
Reset
0x00000000
Access
read/write
Size
32-bit
SRETM Status Register
Address
0xE0041010
Reset
0x00000000
Access
read/write
Size
32-bit
SCRETM System Configuration Register
Address
0xE0041014
Reset
0x00020D09
Access
read only
Size
32-bit
TEEVRETM TraceEnable Event Register
Address
0xE0041020
Reset
0x00000000
Access
read/write
Size
32-bit
TECR1ETM TraceEnable Control 1 Register
Address
0xE0041024
Reset
0x00000000
Access
read/write
Size
32-bit
FFLRETM FIFO Full Level Register
Address
0xE0041028
Reset
0x00000000
Access
read/write
Size
32-bit
CNTRLDVR1ETM Free-running Counter Reload Value
Address
0xE0041140
Reset
0x00000000
Access
read/write
Size
32-bit
SYNCFRETM Synchronization Frequency Register
Address
0xE00411E0
Reset
0x00000400
Access
read only
Size
32-bit
IDRETM ID Register
Address
0xE00411E4
Reset
0x4114F250
Access
read only
Size
32-bit
CCERETM Configuration Code Extension Register
Address
0xE00411E8
Reset
0x18541800
Access
read only
Size
32-bit
TESSEICRETM TraceEnable Start/Stop EmbeddedICE Control Register