The 13 registers of EIC (External Interrupt Controller), from 0x40000800, with their reset value and every field. The WBZ350_SL3 has 2134 registers in 59 peripherals, one page each.
EIC External Interrupt Controller
CTRLAControl A
Address
0x40000800
Reset
0x00
Access
read/write
7–
6–
5–
4CKSEL
3–
2–
1ENABLE
0SWRST
3 fields
Field
Bits
What it does
CKSEL
4
Clock Selection
0 Clocked by GCLK
1 Clocked by LPCLK
ENABLE
1
Enable
SWRST
0
Software Reset
NMICTRLNon-Maskable Interrupt Control
Address
0x40000801
Reset
0x00
Access
read/write
7–
6–
5–
4NMIASYNCH
3NMIFILTEN
2NMISENSE2
1NMISENSE1
0NMISENSE0
3 fields
Field
Bits
What it does
NMIASYNCH
4
Asynchronous Edge Detection Mode
0 Edge detection is clock synchronously operated
1 Edge detection is clock asynchronously operated
NMIFILTEN
3
Non-Maskable Interrupt Filter Enable
NMISENSE
2:0
Non-Maskable Interrupt Sense Configuration
0 No detection
1 Rising-edge detection
2 Falling-edge detection
3 Both-edges detection
4 High-level detection
5 Low-level detection
NMIFLAGNon-Maskable Interrupt Flag Status and Clear