Input stages
The CMOS inputs have very low typical bias current at room temperature. Leakage increases with temperature, and board contamination or high source impedance can dominate the error.
Explore the internal circuitry and functional stages of MCP6002.
Two CMOS input paths, compensated gain and low-power output stages.
Select a stage to see its role and connections
The CMOS inputs have very low typical bias current at room temperature. Leakage increases with temperature, and board contamination or high source impedance can dominate the error.
Each channel has an internal voltage-gain path and frequency compensation.
Each amplifier has a rail-to-rail output stage. Output swing is not exactly equal to the rails, especially as output current rises.