TB6612FNG Reference Tables
Search the TB6612FNG pin reference and manufacturer-referenced specification tables.
Pin reference
Signal names, electrical functions and connection guidance
Scroll within the table to see all columns and rows.
| Pin | Signal | Type | Function & connection |
|---|---|---|---|
| AO1 | Motor output | Physical contact 1 of the AO1 output.Connection guidanceJoin both AO1 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| AO1 | Motor output | Physical contact 2 of the AO1 output.Connection guidanceJoin both AO1 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| PGND1 | Motor-current return | Power ground for the output bridge.Connection guidanceJoin all four PGND contacts to the supply return with low-impedance copper. Keep motor-current paths away from small-signal ground routing. | |
| PGND1 | Motor-current return | Power ground for the output bridge.Connection guidanceJoin all four PGND contacts to the supply return with low-impedance copper. Keep motor-current paths away from small-signal ground routing. | |
| AO2 | Motor output | Physical contact 5 of the AO2 output.Connection guidanceJoin both AO2 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| AO2 | Motor output | Physical contact 6 of the AO2 output.Connection guidanceJoin both AO2 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| BO2 | Motor output | Physical contact 7 of the BO2 output.Connection guidanceJoin both BO2 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| BO2 | Motor output | Physical contact 8 of the BO2 output.Connection guidanceJoin both BO2 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| PGND2 | Motor-current return | Power ground for the output bridge.Connection guidanceJoin all four PGND contacts to the supply return with low-impedance copper. Keep motor-current paths away from small-signal ground routing. | |
| PGND2 | Motor-current return | Power ground for the output bridge.Connection guidanceJoin all four PGND contacts to the supply return with low-impedance copper. Keep motor-current paths away from small-signal ground routing. | |
| BO1 | Motor output | Physical contact 11 of the BO1 output.Connection guidanceJoin both BO1 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| BO1 | Motor output | Physical contact 12 of the BO1 output.Connection guidanceJoin both BO1 contacts on the PCB; connect the motor between its channel output pairs. Both motor terminals are switched. Do not ground one motor terminal. | |
| VM2 | Motor supply | One of three motor-supply contacts.Connection guidanceConnect VM1=24, VM2=13 and VM3=14 to the same motor rail. Operating range 2.5–13.5 V; the 15 V absolute maximum is not a recommended operating voltage. | |
| VM3 | Motor supply | One of three motor-supply contacts.Connection guidanceConnect VM1=24, VM2=13 and VM3=14 to the same motor rail. Operating range 2.5–13.5 V; the 15 V absolute maximum is not a recommended operating voltage. | |
| PWMB | PWM command | Duty-cycle input for channel B.Connection guidanceConnect to a controller PWM output; use a frequency no higher than 100 kHz. With opposite direction inputs, PWM LOW selects short brake rather than high-impedance coast. | |
| BIN2 | Direction command | One of the two direction controls for channel B.Connection guidanceUse defined HIGH/LOW logic together with PWM and STBY; see the control table. Internal 200 kΩ pulldown. HIGH requires at least 0.7 × VCC. | |
| BIN1 | Direction command | One of the two direction controls for channel B.Connection guidanceUse defined HIGH/LOW logic together with PWM and STBY; see the control table. Internal 200 kΩ pulldown. HIGH requires at least 0.7 × VCC. | |
| GND | Small-signal ground | Reference for control inputs and logic supply.Connection guidanceJoin the common ground while keeping motor return currents out of the control path. | |
| STBY | Active-LOW standby | LOW places both channels into standby with high-impedance outputs.Connection guidanceDrive HIGH to operate. Keep LOW during initialization. Internal 200 kΩ pulldown. Standby is not the short-brake mode. | |
| VCC | Logic supply | Powers the small-signal control logic.Connection guidanceUse the controller logic rail; the example uses 3.3 V. Add local 100 nF and 10 µF bypass. Operating range 2.7–5.5 V. Input thresholds track VCC. | |
| AIN1 | Direction command | One of the two direction controls for channel A.Connection guidanceUse defined HIGH/LOW logic together with PWM and STBY; see the control table. Internal 200 kΩ pulldown. HIGH requires at least 0.7 × VCC. | |
| AIN2 | Direction command | One of the two direction controls for channel A.Connection guidanceUse defined HIGH/LOW logic together with PWM and STBY; see the control table. Internal 200 kΩ pulldown. HIGH requires at least 0.7 × VCC. | |
| PWMA | PWM command | Duty-cycle input for channel A.Connection guidanceConnect to a controller PWM output; use a frequency no higher than 100 kHz. With opposite direction inputs, PWM LOW selects short brake rather than high-impedance coast. | |
| VM1 | Motor supply | One of three motor-supply contacts.Connection guidanceConnect VM1=24, VM2=13 and VM3=14 to the same motor rail. Operating range 2.5–13.5 V; the 15 V absolute maximum is not a recommended operating voltage. |
No pins match these filters. Try another signal name or reset the filters.
Supply and operating limits
Recommended conditions versus absolute ratings
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VM motor rail | 2.5–13.5 V | 5 V example; allow margin for regenerated energy |
| VCC logic rail | 2.7–5.5 V | 3.3 V example |
| Output current, no PWM | 1.0 A maximum | Operating table at VM ≥4.5 V |
| Output current, low VM | 0.4 A maximum | Operating table at 2.5 V ≤ VM <4.5 V, without PWM |
| PWM switching | Up to 100 kHz | Use a suitable controller and motor |
| Ambient range | −20°C to +85°C | Derate power as ambient rises |
| Absolute motor / logic supply | 15 V / 6 V | Stress limits, not operating setpoints |
| Absolute current headline | 1.2 A per channel | Thermal and pulse conditions still apply |
No specifications match. Try a parameter name or a unit.
Supply levels, current, duty cycle and PCB thermal design must be considered together.
Input thresholds and current
Control inputs are referenced to VCC
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| HIGH / LOW thresholds | ≥0.7×VCC / ≤0.3×VCC | At 3.3 V: ≥2.31 V / ≤0.99 V |
| Input pulldowns | 200 kΩ nominal | IN1, IN2, PWM and STBY |
| Logic supply current | 1.1 mA typical; 1.8 mA maximum | VCC=3 V, VM=5 V, STBY=HIGH |
| Standby logic current | 1 µA maximum | STBY=LOW |
| Standby motor-rail current | 1 µA maximum | Specified standby conditions |
| Input HIGH current | 5 / 15 / 25 µA | Minimum / typical / maximum at VIN=3 V |
No specifications match. Try a parameter name or a unit.
A 3.3 V controller is directly compatible when VCC is also 3.3 V.
Direction, brake and standby
Tuple order: IN1 · IN2 · PWM · STBY
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| HIGH LOW HIGH HIGH | OUT1 HIGH; OUT2 LOW | One drive polarity |
| LOW HIGH HIGH HIGH | OUT1 LOW; OUT2 HIGH | Opposite drive polarity |
| Opposite inputs; PWM LOW; STBY HIGH | Both outputs LOW | Short brake during the PWM off interval |
| HIGH HIGH; PWM either; STBY HIGH | Both outputs LOW | Short brake |
| LOW LOW HIGH HIGH | Both outputs high impedance | Stop / coast |
| Any inputs; STBY LOW | Both outputs high impedance | Standby |
| Other combinations | Use the documented control states | Do not assign behavior from a different driver truth table |
No specifications match. Try a parameter name or a unit.
CW/CCW depends on motor wiring; the electrical polarity is the useful invariant.
Losses and thermal limits
Do not treat a peak-current rating as continuous current
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Drive-path drop at 1 A | 0.5 V typical; 0.7 V maximum | VCC=VM=5 V, total upper + lower switches |
| Drive-path drop at 0.3 A | 0.15 V typical; 0.21 V maximum | VCC=VM=5 V |
| One-channel estimate at 1 A | 0.5 W typical conduction | Before switching losses and temperature rise |
| Two-channel estimate at 0.3 A each | 0.09 W typical conduction | 2×0.3 A×0.15 V; illustrative calculation |
| Absolute pulsed current | 2 A, 20 ms, duty ≤20% | Specified continuous-pulse condition |
| Absolute single pulse | 3.2 A, 10 ms | Not a continuous operating value |
| Dissipation at 25°C | 0.78 / 0.89 / 1.36 W | IC only / specified 50×50 mm PCB / specified 76.2×114.3 mm PCB |
| Thermal shutdown / hysteresis | 175°C / 20°C | Design targets, not guaranteed operating temperatures |
| Low-voltage detect / recovery | 1.9 V / 2.2 V | Design-target values |
No specifications match. Try a parameter name or a unit.
Choose motor stall current and protection so normal operation remains within electrical and thermal limits.
Two-motor example
5 V motor supply and 3.3 V controller
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Motor A | AO1 pins 1+2; AO2 pins 5+6 | Join each duplicated pair before the motor |
| Motor B | BO1 pins 11+12; BO2 pins 7+8 | Both terminals are driven |
| Motor rail | VM1=24, VM2=13, VM3=14 | Connect all three to 5 V |
| Logic rail | VCC=20 | Connect 3.3 V; controller uses the same level |
| Supply bypass | 10 µF + 100 nF on each rail | Place close to the IC and keep loop area small |
| Ground | PGND1=3+4, PGND2=9+10, GND=18 | Common return with sensible current routing |
| Channel A controls | AIN1=21, AIN2=22, PWMA=23 | Defined controller outputs |
| Channel B controls | BIN1=17, BIN2=16, PWMB=15 | Defined controller outputs |
| Global standby | STBY=19 | Keep LOW until controller initialization is complete |
No specifications match. Try a parameter name or a unit.
Duplicate output pins are physical contacts of the same node, not independently controlled outputs.
SSOP physical package
Bare IC, not a breakout-board header
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Package name | SSOP24-P-300-0.65A | Surface mount; 24 gull-wing leads |
| Molded body | 5.6×7.8 mm nominal | Package length may reach 8.3 mm overall |
| Lead pitch / span | 0.65 mm / 7.6 mm nominal | Pin 1 marked by the top-view dot |
| Height | 1.6 mm maximum | Follow seating-plane and assembly tolerances |
| Original copper lands | 1.50×0.40 mm | 7.00 mm row centers; check assembly process |
| Exposed pad | None in this package | Do not add a fictitious center contact |
| Footprint download | KiCad .kicad_mod | Original authored footprint with all 24 pad numbers |
No specifications match. Try a parameter name or a unit.
Mechanical reference: Toshiba package drawing; the download is an original land-pattern interpretation.
No matching rowsTry a pin name, parameter, unit or test condition, or reset the filters.