NC
Function
Unused contact
How to connect
Leave unconnected.
Explore LM723 pins, signal names, electrical functions and connection guidance for each package.
Select a pin to explore its connection
Click a lead or use the arrow keys. Top view
Unused contact
Leave unconnected.
Current-limit transistor base
Connect to OUT10 before the 10 Ω sense resistor.
Current-sense transistor emitter
Connect to the regulated output after the sense resistor.
Error amplifier feedback
Connect to the regulated output through 3 kΩ; connect compensation capacitor here.
Error amplifier reference input
Connect to the 4.3 kΩ / 10 kΩ reference-divider junction.
Nominal 7.15 V reference
Connect 4.3 kΩ to IN+5; 10 kΩ from IN+5 to ground.
Control-circuit return
Connect to ground.
Unused contact
Leave unconnected.
Internal zener connection
Leave open in this positive-output example.
Internal pass emitter
Connect CL2 and the input side of the 10 Ω sense resistor.
Pass-transistor collector
Connect to +12 V.
Control-circuit positive supply
Connect to +12 V; bypass locally to ground.
Frequency compensation
Connect 100 pF between COMP13 and IN−4.
Unused contact
Leave unconnected.