Skip to datasheet
Latching SPST on-off switch

Switch (Toggle, Rocker and DIP) Specifications

Review Switch (Toggle, Rocker and DIP) electrical specifications, operating conditions and package details.

Package view

Key specifications

Pick the switch by the load: a DIP switch sets logic levels (50 mA), a rocker or toggle switches power. Wire the switch in the positive feed so the load is dead when it is off, and stay inside the rating for the kind of load (lamps and motors draw several times their running current at switch-on).

Contact rating50 mA – 20 A DIP · rocker 1 A · toggles 3–20 A (resistive)
Contact resistance10–100 mΩ maximum, initial
Rated voltage24–250 V · DIP 24 V DC, toggles 28–30 V DC / 120–250 V AC, rocker 250 V AC
Life6 000–100 000 cycles by switch

Operating profile

Supply, signals and operating conditions

Switch (Toggle, Rocker and DIP) operating profile
ParameterValueConditions / notes
Selected packageMiniature toggle7101SYZQE · 2 circuit terminals
ContactSPST, latchingStays where it is put
Example circuit12 V · 0.5 AToggle or rocker in a lamp feed
Use these values with the stated grade and test conditions.

Package details

7101SYZQE · Miniature toggle

Selected package
Selected Switch (Toggle, Rocker and DIP) physical package
PropertyDetails
ManufacturerC&K (Littelfuse)
Part number7101SYZQE
PackageMiniature toggle
Connections2 pins
MountingPanel mount · wired to a 2-pin header
Lead pitch2.54 mm pitch
Package codeswitch-connector
Thermal referenceContact heating at the rating: (5 A)² × 10 mΩ = 0.25 W

Selected parts and terminals

Manufacturer scope and page conventions

Scroll sideways to see all columns.

ParameterValueConditions / notes
Reference partsC&K (Littelfuse) 7101SYZQE · Shou Han KCD11-2P · CTS 206-1S · E-Switch 200MSP6T1B1M2QE · 100SP1T1B1M1QE · ST4SP2DT1C2One sheet each
Contact formSPST on-off, latchingThe C&K and E-Switch 200 / 100 toggles are SPDT: the common terminal 2 and one end terminal make the on-off switch
Terminal 1Toggle lug 1 (E-Switch: terminal 3) · rocker tab · DIP pin 1 (square)ProTech pin 1 · footprint pad 1
Terminal 2Toggle terminal 2 (common) · rocker tab · DIP pin 2ProTech pin 2 · footprint pad 2
Panel switchesToggles and rocker wired to a 2-pin headerTheir own lugs are not PCB pins
Proteus symbolSWITCH2 pins; ProTech’s Toggle Switch models it

A panel switch’s wires go to the header; the header is what the PCB carries.

The six switches

From each manufacturer’s sheet · the numbers ProTech’s model and checks use

Scroll sideways to see all columns.

SpecificationC&K (Littelfuse) 7101SYZQEShou Han KCD11-2PCTS 206-1SE-Switch 200MSP6T1B1M2QEE-Switch 100SP1T1B1M1QEE-Switch ST4SP2DT1C2
Contact rating (resistive)5 A at 120 V AC or 28 V DC; 2 A at 250 V AC (silver)1 A at 250 V AC (no DC rating in the sheet)50 mA at 24 V DC switching; 100 mA or 50 V DC carrying3 A at 120 V AC or 28 V DC; 1 A at 250 V AC (silver)5 A at 120 V AC or 28 V DC; 2 A at 250 V AC (silver)20 A at 6–30 V DC; 16(8) A at 125/250 V AC
Minimum loadgold contacts: 0.4 VA max at 20 Vnot in datasheetnot in datasheetgold contacts: 0.4 VA max at 20 Vgold contacts: 0.4 VA max at 20 Vnot in datasheet
Contact resistance10 mΩ maximum (initial)100 mΩ maximum (initial)50 mΩ maximum (initial)20 mΩ maximum (initial)10 mΩ maximum (initial)50 mΩ maximum (initial)
Insulation resistance≥ 10⁹ Ω≥ 100 MΩ at 500 V DC≥ 1000 MΩ≥ 1000 MΩ≥ 1000 MΩ≥ 50 MΩ
Dielectric strength1000 V rms1500 V AC between terminals500 V AC for 1 min1000 V rms1000 V rms1500 V rms
Operationlever, two positions 25° each siderocker, two positions (O and —)slide, two positionslever, two positions 25° each sidelever, two positions 25° each side; torque max 5 kg·cm17 mm metal bat, two positions (OFF-ON)
Travellever 10.67 mm above the bushingrocker 12 × 6.3 mm, about 3 mm proudtravel 2.03 mmlever 9.40 mm above the bushinglever 10.41 mm above the bushingbat 17.00 mm above the bushing
Life100 000 electrical cycles at full load10 000 mechanical cycles10 000 cycles at 50 mA, 24 V DC30 000 mechanical, 6 000 at full load40 000 mechanical, 6 000 at full power10 000 electrical cycles
Contact bouncenot in the sheetnot in the sheetnot in the sheetnot in the sheetnot in the sheetnot in the sheet
Operating temperature−30 to +85 °C−25 to +85 °C−55 to +85 °C−40 to +85 °C−40 to +85 °C−10 to +55 °C
Sizecase 12.70 × 6.86 mm, 1/4-40 bushing, hex nutbezel 15 × 10.5 mm, panel cut-out 14 × 8.8 mm9.78 × 3.96 mm, 7.6 mm highcase 8.13 × 8.64 mm, 10-48 bushing 5.59 mm, nut 7.00 mm A/Fcase 12.70 × 8.89 mm, 1/4-40 bushing 8.89 mmcase 28.80 × 21.00 mm, 15/32-32 bushing Ø12 mm, IP68
Terminals4.70 mm (SPDT; pins 2 common and 1 used for ON-OFF)5.0 mm (2 pins, snap-in panel mount)7.62 mm row spacing (2 pins)2.54 mm (PC pins 1-2-3; pins 2 common and 3 used for OFF-ON)4.70 mm (solder lugs 1-2-3; pins 2 common and 3 used for ON-OFF)1/4 in quick-connect tabs (panel mount)
Lookchrome bat lever, nickel-plated hex nut and bushing, dark caseblack bezel and rocker, O and bar marksblue housing, white slider, ON arrowside view: case, nickel bushing and nut, chrome bat lever; its tip lit red OFF, green ON (ProTech's display; the real bat is plain)side view: case, nickel bushing and nut, chrome bat lever; its tip lit red OFF, green ON (ProTech's display; the real bat is plain)side view: case, nickel bushing and nut, chrome bat lever; its tip lit red OFF, green ON (ProTech's display; the real bat is plain)

Contact resistance is the initial maximum; it rises with wear and contamination. Ratings are for resistive loads.

How ProTech models it

The same numbers drive the simulator, its checks and this page

Scroll sideways to see all columns.

ParameterValueConditions / notes
ClosedRc of the switch chosen, between pins 1 and 210 mΩ toggle · 100 mΩ rocker · 50 mΩ DIP · 20 mΩ / 10 mΩ / 50 mΩ E-Switch 200 / 100 / ST4
OpenNo branchInsulation resistance not modelled
Rating checkWarns above the switch’s current or voltage5 A / 28 V · 1 A / 250 V · 50 mA / 24 V · 3 A / 28 V · 5 A / 28 V · 20 A / 30 V
PositionSaved with the circuitA click or Enter flips it while running
SizeDrawn at true sizeToggle 12.70 × 6.86 mm, rocker 15 × 10.5 mm, DIP 9.78 × 3.96 mm, E-Switch toggles 8.13, 12.70 and 28.80 mm wide
LED toggle switchThe E-Switch 200, 100 and ST4 (small, medium, large)Its lit tip, red OFF and green ON, is ProTech’s display; the real bat is plain

Change the switch in Properties: the drawing, rating, contact resistance and PCB footprint follow it.

Switching a 12 V, 0.5 A lamp feed

Toggle or rocker in the positive wire

Scroll sideways to see all columns.

ParameterValueConditions / notes
Toggle drop5 mV0.5 A × 10 mΩ
Toggle contact heating2.5 mW(0.5 A)² × 10 mΩ
Rocker drop50 mV0.5 A × 100 mΩ
Rocker contact heating25 mW(0.5 A)² × 100 mΩ
Rocker on DCCheck firstThe KCD11 sheet gives 1 A at 250 V AC and no DC rating
DIP switchNeverRated 50 mA switching; use it for logic inputs

Lamps draw about ten times their running current when cold: derate the switch for them.

Package

7101SYZQE · Miniature toggle

Scroll sideways to see all columns.

ParameterValueConditions / notes
Togglecase 12.70 × 6.86 mm, 1/4-40 bushing, hex nut4.70 mm (SPDT; pins 2 common and 1 used for ON-OFF)
Rockerbezel 15 × 10.5 mm, panel cut-out 14 × 8.8 mm5.0 mm (2 pins, snap-in panel mount)
DIP switch9.78 × 3.96 mm, 7.6 mm high7.62 mm row spacing (2 pins)
E-Switch 200case 8.13 × 8.64 mm, 10-48 bushing 5.59 mm, nut 7.00 mm A/F2.54 mm (PC pins 1-2-3; pins 2 common and 3 used for OFF-ON)
E-Switch 100case 12.70 × 8.89 mm, 1/4-40 bushing 8.89 mm4.70 mm (solder lugs 1-2-3; pins 2 common and 3 used for ON-OFF)
E-Switch ST4case 28.80 × 21.00 mm, 15/32-32 bushing Ø12 mm, IP681/4 in quick-connect tabs (panel mount)
Header (panel switches)2.54 mm pitch, Ø1 mm drillKiCad PinHeader_1x02_P2.54mm_Vertical
DIP footprint7.62 mm row spacing, Ø0.8 mm drillKiCad SW_DIP_SPSTx01_Slide_9.78x4.72mm_W7.62mm_P2.54mm

Footprints are KiCad’s, the same as ProTech’s PCB page.

Connections by function

Select a pin for its function, connection guidance and electrical notes.

Switch contact2 pins

Read the conditions with every value

Typical values describe stated test conditions. Absolute maximum ratings are stress limits, not operating targets.

Official PDF datasheet

Component view