Pin reference
Signal names, electrical functions and connection guidance
Scroll within the table to see all columns and rows.
| Pin | Signal | Type | Function & connection |
|---|---|---|---|
| MR | Input | Active-low manual-reset input with internal pull-up current.Connection guidanceConnect WDO here in the illustrated automatic-reset circuit. A low pulse of at least 150 ns triggers reset; do not short a push-pull WDO output with a manual switch. | |
| VCC | Power | Supply input for the MAX706 supervisor.Connection guidanceConnect to regulated 5 V; place a 100 nF bypass capacitor to GND nearby. Electrical tables use 4.5–5.5 V; the low-voltage operating range describes supervision during supply collapse. | |
| GND | Power return | Common reference for the supply and all signal levels.Connection guidanceConnect to controller ground with a short return. | |
| PFI | Analog input | Noninverting power-fail comparator input; nominal threshold 1.25 V.Connection guidanceTie to VCC in this watchdog-only example, or use a reviewed divider for another rail. Do not leave unused PFI floating; the manufacturer permits tying it to GND or VCC. | |
| PFO | Output | Active-low power-fail output, asserted when PFI is below its threshold.Connection guidanceUnused in this example: leave the output unconnected. 1.20–1.30 V comparator threshold; this is separate from the VCC reset threshold. | |
| WDI | Input | Watchdog activity input; either rising or falling transitions clear the timer.Connection guidanceDrive with 0–5 V heartbeat transitions every 0.5 s after startup. A floating or three-stated WDI disables the watchdog. At 5 V, LOW ≤0.8 V and HIGH ≥3.5 V. | |
| RESET | Output | Active-low reset output for startup, brownout and manual-reset events.Connection guidanceConnect to an active-low reset input on the supervised controller. WDO must connect to MR for watchdog expiry to cause RESET. Release delay is 140–280 ms after the cause clears. | |
| WDO | Output | Active-low watchdog output; also goes low when VCC is below its reset threshold.Connection guidanceConnect to MR for automatic reset; alternatively use a suitable fault input. Watchdog timeout 1.00–2.25 s, 1.60 s typical. Low-line assertion is not evidence of a missing heartbeat. |
No pins match these filters. Try another signal name or reset the filters.
Reference and package scope
MAX706 C-grade DIP and SOIC only
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Through-hole | MAX706CPA+ · P8+1 | PDIP-8; 2.54 mm pitch |
| Surface-mount | MAX706CSA+ · S8+2 | SOIC-8; 1.27 mm pitch |
| Reference | 19-4334 Rev.11, July 2018 | MAX705–MAX708 / MAX813L family datasheet |
| Pins | MR1, VCC2, GND3, PFI4, PFO5, WDI6, RESET7, WDO8 | DIP and SOIC use the same pin order |
| Other family members | MAX707/MAX708 lack this watchdog | Do not apply their reset-output pin functions here |
| µMAX package | Different pin assignment | Not offered as an interchangeable view on this page |
No specifications match. Try a parameter name or a unit.
The model shown is a concrete example of watchdog supervision, not a universal pinout.
Supply and reset supervision
Selected MAX706C at the specified operating conditions
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Electrical test supply | 4.5–5.5 V | Normal 5 V system |
| Low-voltage operating range | 1.0–5.5 V | C grade; supervision during power-up/down, not a 1 V logic application |
| Supply current | 150 µA typical; 350 µA maximum | MAX706C |
| Reset threshold | 4.25 /4.40 /4.50 V | Minimum /typical /maximum |
| Threshold hysteresis | 40 mV typical | Supply reset comparator |
| Reset release delay | 140 /200 /280 ms | Minimum /typical /maximum after supply/MR recovery |
No specifications match. Try a parameter name or a unit.
Supply supervision is independent of the missing-heartbeat timer.
Watchdog timing and input
MAX706, 5 V logic levels
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Timeout | 1.00 /1.60 /2.25 s | Minimum /typical /maximum |
| Valid WDI pulse width | 50 ns minimum | VIL 0.4 V; VIH 0.8 ×VCC test levels |
| WDI LOW /HIGH | ≤0.8 V /≥3.5 V | At VCC 5 V |
| WDI current, HIGH | 50 µA typical;150 µA maximum | WDI = VCC |
| WDI current, LOW | −50 µA typical;−150 µA limit | WDI = 0 V |
| Timer clearing | Either edge, RESET assertion or three-state | No window timing requirement |
| Disabled state | WDI floating or three-stated | Timer stays cleared |
No specifications match. Try a parameter name or a unit.
A 3.3 V HIGH is below the stated 3.5 V minimum at a 5 V supply; use compatible drive.
Manual reset and output drive
Signal loading and output polarity
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| MR pull-up current | 100 /250 /600 µA | Minimum /typical /maximum with MR 0 V |
| MR minimum pulse | 150 ns | Active LOW |
| MR LOW /HIGH | ≤0.8 V /≥2.0 V | Input thresholds |
| MR to RESET delay | 250 ns maximum | Specified propagation delay |
| RESET LOW | 0.4 V maximum | ISINK 3.2 mA |
| WDO LOW | 0.4 V maximum | ISINK 1.2 mA |
| RESET /WDO HIGH | VCC −1.5 V minimum | ISOURCE 800 µA |
| RESET at VCC 1 V | 0.3 V maximum | C grade, ISINK 50 µA |
No specifications match. Try a parameter name or a unit.
Check the supervised controller reset input and avoid output contention.
Separate power-fail comparator
Optional additional rail monitoring
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| PFI threshold | 1.20 /1.25 /1.30 V | Minimum /typical /maximum at VCC 5 V |
| PFI leakage | −25 to +25 nA; +0.01 nA typical | Input current |
| PFO LOW | 0.4 V maximum | ISINK 3.2 mA |
| PFO HIGH | VCC −1.5 V minimum | ISOURCE 800 µA |
| Unused PFI | Tie to VCC or GND | This example chooses VCC |
| Unused PFO | Leave unconnected | Output; do not drive it externally |
No specifications match. Try a parameter name or a unit.
A divider can monitor another supply, with threshold and resistor tolerances included.
Absolute limits and temperature
Stress limits are not recommended operating conditions
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VCC absolute range | −0.3 to +6.0 V | Referenced to GND |
| Other inputs | −0.3 V to VCC +0.3 V | PFI/MR exception requires current <10 mA; not used here |
| Supply /ground current | 20 mA | Absolute limit per supply or ground connection |
| Output current | 20 mA | Absolute stress; use specified logic-loading limits |
| PDIP /SO dissipation at 70°C | 727 /471 mW | Derate 9.09 /5.88 mW per °C above70°C |
| Selected operating ambient | 0–70°C | CPA+ and CSA+ commercial grades |
| Storage | −65 to +160°C | Unpowered |
No specifications match. Try a parameter name or a unit.
Package cooling and input/output loading must be evaluated together.
Automatic-reset teaching circuit
5 V controller with a dedicated reset input
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VCC2 /GND3 | 5 V /common ground | 100 nF local bypass is an example layout choice |
| WDI6 | 0–5 V; edge every 0.5 s | Heartbeat from useful application work |
| WDO8 →MR1 | Explicit feedback connection | Watchdog expiry triggers RESET |
| RESET7 | Controller active-low reset input | Check logic compatibility and bidirectional-reset restrictions |
| PFI4 /PFO5 | VCC /unconnected | Comparator unused |
| Heartbeat interval margin | 1.00 s /0.50 s = 2 | Against minimum timeout, before jitter |
| Typical timeout after last edge | 1.60 s | Real device can expire anywhere within1.00–2.25s |
No specifications match. Try a parameter name or a unit.
This is an illustrated reference, not a firmware emulator or measured live simulation.
Package and footprint dimensions
Manufacturer outlines and original TEP lands
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| PDIP outline | 21-0043 Rev F · P8+1 | Body length8.84–9.91mm; width6.10–7.87mm; bodyheight3.18–4.45mm |
| PDIP pitch /formed rows | 2.54 /7.62 mm | Nominal; leads are formed for insertion |
| PDIP physical lead | 0.381–0.56mm width;0.20–0.355mm thickness | Exposed length2.921–3.81mm |
| PDIP starting lands | 1.80mm pad;1.00mm finished hole | Board and assembly allowances require review |
| SOIC outline | 21-0041 Rev V · S8+2 | Body4.8–5.0 ×3.8–4.0mm; overall span5.8–6.2mm |
| SOIC pitch /lead width | 1.27mm /0.35–0.49mm | Lead thickness0.19–0.25mm |
| SOIC starting lands | 1.55 ×0.60mm;5.40mm row centres | Original pattern, not a manufacturer-certified footprint |
No specifications match. Try a parameter name or a unit.
Check mask, paste, courtyard and purchased-part tolerances before manufacture.