Skip to datasheet
System supervision · MAX706 example

Watchdog Timer Working Principle

Learn how Watchdog Timer works with an illustrated explanation and practical readings.

Package view

Watchdog Timer at a glance

Follow the labeled connections and functional stages

Watchdog Timer working principle: illustrated functional stages, basic circuit and connections
Select the diagram to read it at full resolution.

How it works

4 stages · Explore one step at a time

Step 1 / 4

Start with a stable supply

At power-up, RESET stays low until VCC exceeds the reset threshold and the reset-release delay finishes. The MAX706 threshold is 4.40 V typical; its 4.25–4.50 V limits matter.

Step 2 / 4

Report useful progress

Drive WDI through a rising or falling edge after meaningful application work. The example uses an edge every 0.5 s. A free-running interrupt that toggles forever can conceal a stalled main program.

Step 3 / 4

Detect missing transitions

With WDI driven but unchanged, the watchdog expires after 1.00–2.25 s. Floating WDI disables this function; do not mistake a disconnected heartbeat for fault detection.

Step 4 / 4

Route the fault to reset

The pictured connection joins WDO to MR, making watchdog expiry trigger the active-low RESET output. Without that connection, WDO is a separate fault signal and does not itself assert RESET.