PIN 1 · Supply
SupplyVDD
Function
Positive supply input.
How to connect
Connect to a 3.3–5.5 V rail with local bypassing. The circuit shown uses 5 V.
Electrical note
The GPIO must tolerate the data pullup voltage.
Explore DHT22 pins, signal names, electrical functions and connection guidance for each package.
Select a pin to explore its connection
Click a lead or use the arrow keys. Front view · vent face toward you · leads down
Positive supply input.
Connect to a 3.3–5.5 V rail with local bypassing. The circuit shown uses 5 V.
The GPIO must tolerate the data pullup voltage.
Timed single-wire measurement interface.
Connect a compatible GPIO and a pullup; release the line for the sensor response.
This is not I²C or an addressed Dallas 1-Wire interface.
Unused physical contact.
Leave open.
Common supply and logic reference.
Connect to the controller return.