Power and reference
Connect both VDD and VREF to 3.3 V, join the grounds and place the 1 µF bypass nearby.
Build a basic MCP3008 circuit with labeled pins, component values and connection guidance.
A physical MCP3008 and a 3.3 V controller share a quiet supply.
Follow the component values and pin connections
Connect both VDD and VREF to 3.3 V, join the grounds and place the 1 µF bypass nearby.
Use MOSI→DIN, DOUT→MISO, SCLK→SCLK and a separate chip-select line.
Send 01 80 00 to select single-ended CH0. Combine the ten returned data bits; raise CS between measurements.