Power and bypass
Use regulated 5 V, common ground, 100 nF and 100 µF near the IC.
Build a basic TM1637 circuit with labeled pins, component values and connection guidance.
5 V host, bidirectional data, pull-ups and local bypassing.
Follow the component values and pin connections
Use regulated 5 V, common ground, 100 nF and 100 µF near the IC.
Pull CLK and DIO up through 10 kΩ and use a compatible host.
Write the six display bytes with 0x40 / 0xC0, then enable with 0x8B. K1/K2 are unused in this example.