SHT40 Reference Tables
Search the SHT40 pin reference and manufacturer-referenced specification tables.
Pin reference
Signal names, electrical functions and connection guidance
Scroll within the table to see all columns and rows.
| Pin | Signal | Type | Function & connection |
|---|---|---|---|
| SDA | Bidirectional data | I²C serial data.Connection guidanceConnect to the controller SDA with a pullup to the sensor logic rail. Open-drain data line; the sensor does not stretch SCL. | |
| SCL | Clock input | I²C clock from the controller.Connection guidanceConnect to controller SCL and the bus pullup. | |
| VDD | Supply | Positive sensor supply.Connection guidanceUse 1.08–3.6 V; the example uses 3.3 V and a 100 nF bypass. Do not power the bare sensor from 5 V. | |
| VSS | Ground | Supply and interface reference.Connection guidanceConnect to the controller ground. |
No pins match these filters. Try another signal name or reset the filters.
Supply and interface
Bare SHT40-AD1B; no onboard regulator
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Operating supply | 1.08–3.6 V | 3.3 V in this example |
| Example decoupling | 100 nF | Place close to VDD/VSS |
| Idle / measurement current | 80 nA / 320 µA typical | Heater off; measurement current 500 µA maximum |
| I²C address | 0x44, seven-bit | Fixed by the AD variant; no ADDR pin |
| Other address variants | BD → 0x45; CD → 0x46 | Different ordering codes, not software address settings |
| Clock stretching | Not supported | Delay or retry after a busy NACK |
| I²C clock | Up to 1 MHz | Meet the bus electrical limits |
| Pullups | 4.7 kΩ in this short-bus example | Calculate for actual bus capacitance and voltage |
No specifications match. Try a parameter name or a unit.
A breakout may include extra circuitry; its connector ratings do not change the bare IC limits.
SHT40 measurement performance
June 2026 manufacturer reference
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Humidity accuracy | ±1.8%RH typical | Maximum error depends on the conditions curve |
| Temperature accuracy | ±0.2°C typical | Do not substitute SHT45 specifications |
| Specified ranges | 0–100%RH; −40°C to +125°C | Follow normal operating and handling guidance |
| Humidity response | 4 s typical to 63% | At 25°C and 1 m/s airflow |
| Temperature response | 2 s typical to 63% | Depends on the mounting and heat flow |
| High-repeatability noise | 0.08%RH / 0.04°C typical | Different from absolute measurement error |
No specifications match. Try a parameter name or a unit.
Digital resolution, repeatability and accuracy are separate specifications.
Commands and wait times
Single-byte commands; temperature precedes humidity
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| High precision | 0xFD · 8.3 ms maximum | Six response bytes |
| Medium precision | 0xF6 · 4.5 ms maximum | Six response bytes |
| Low precision | 0xE0 · 1.6 ms maximum | Six response bytes |
| Read serial number | 0x89 | Two 16-bit words with CRC bytes |
| Soft reset | 0x94 | Allow 1 ms before another command |
| Power-up | 1 ms maximum | After the rail reaches the valid threshold |
No specifications match. Try a parameter name or a unit.
Use a bounded retry policy instead of assuming every transaction immediately succeeds.
CRC and conversion formulas
Use the SHT4x humidity offset
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Six-byte response | T high, T low, T CRC, RH high, RH low, RH CRC | Big-endian unsigned words |
| Temperature | T = −45 + 175 × ST / 65535 | Result in °C |
| Humidity | RH = −6 + 125 × SRH / 65535 | Result in %RH; clamp the displayed value to 0–100 |
| CRC-8 | Polynomial 0x31, initial 0xFF | No reflection; final XOR zero; one CRC per word |
| Known CRC test | BE EF → 92 hex | Manufacturer test vector |
| Illustrative frame | 66 66 93 80 00 A2 hex | 25.00°C and approximately 56.50%RH |
| SHT31 comparison | Same example RH word gives a different value | Do not reuse its 100×raw/65535 equation |
No specifications match. Try a parameter name or a unit.
Reject an incomplete packet or either incorrect CRC.
Built-in heater
Temporary maintenance, not ambient sensing
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Nominal heater levels | 20, 110 or 200 mW at 3.3 V | Actual power and current depend on supply |
| 200 mW commands | 0x39 for 1 s; 0x32 for 0.1 s | Heater switches off automatically |
| 110 mW commands | 0x2F for 1 s; 0x24 for 0.1 s | Heater switches off automatically |
| 20 mW commands | 0x1E for 1 s; 0x15 for 0.1 s | Heater switches off automatically |
| Maximum duty cycle | 10% | Plan the off-time between pulses |
| Ambient restriction | Operate heater below 65°C ambient | Sensor temperature must remain below 125°C |
| Measurement meaning | Heated result is not ambient temperature/RH | Normal sensor accuracy specifications do not apply while heating |
| Power design | Allow the specified heater current | The 200 mW setting has 100 mA maximum in the electrical table |
No specifications match. Try a parameter name or a unit.
Allow thermal recovery before treating the next reading as an ambient measurement.
Contacts and board layout
Small package; specific thermal requirements
Scroll within the table to see all columns and rows.
| Parameter | Value | Conditions / notes |
|---|---|---|
| 1 SDA / 2 SCL | Controller data / clock | Pull up to the compatible sensor rail |
| 3 VDD / 4 VSS | Supply / ground | Do not reverse the footprint orientation |
| Body | 1.5 × 1.5 × 0.54 mm nominal | DFN-4 with centered sensing opening |
| Signal lands | 0.5 × 0.3 mm; 0.8 mm pitch | 1.4 mm between pad-row centers |
| Center die pad | Do not solder or add a copper land underneath | Manufacturer recommendation to preserve heater function |
| Copper below sensor | Keep clear except for its four lands | Apply the clearance in the PCB layout |
| Sensing opening | Keep uncovered and uncontaminated | Do not coat the sensing cavity |
No specifications match. Try a parameter name or a unit.
The downloadable footprint deliberately contains four signal pads and no central copper pad.
No matching rowsTry a pin name, parameter, unit or test condition, or reset the filters.