NC
Function
No internal connection for the selected fourteen-pin package.
How to connect
Leave open; do not connect to ground.
Explore LM319 pins, signal names, electrical functions and connection guidance for each package.
Select a pin to explore its connection
Click a lead or use the arrow keys. Top view
No internal connection for the selected fourteen-pin package.
Leave open; do not connect to ground.
No internal connection for the selected fourteen-pin package.
Leave open; do not connect to ground.
Emitter return for comparator 1 output transistor.
Connect to the common 0 V return in this example.
Separate from the analog negative supply pin; observe every rail-to-ground rating.
Positive input for comparator 1.
Apply VIN = 1.50 V.
At a 5 V supply both inputs must remain between 1 V and 3 V.
Threshold input for comparator 1.
Connect the 2.00 V reference.
Input polarity controls the open-collector state.
Negative supply for both comparator input/gain paths.
Connect to 0 V in the shown single-supply circuit.
In split-supply use this can differ from the output-stage returns.
Sinks current when IN+ is lower than IN−; releases when IN+ is higher.
Leave unused output open in the illustrated circuit.
No internal high-level driver; external pull-up is required to observe HIGH.
Emitter return for comparator 2 output transistor.
Connect to the common 0 V return in this example.
Separate from the analog negative supply pin; observe every rail-to-ground rating.
Positive input for comparator 2.
Tie to the same 1.50 V VIN node.
At a 5 V supply both inputs must remain between 1 V and 3 V.
Threshold input for comparator 2.
Connect the 2.00 V reference.
Input polarity controls the open-collector state.
Positive supply shared by both comparators.
Connect regulated +5 V and bypass locally with 100 nF to pin 6.
Sinks current when IN+ is lower than IN−; releases when IN+ is higher.
Add a 10 kΩ pull-up to +5 V and a high-impedance meter.
No internal high-level driver; external pull-up is required to observe HIGH.
No internal connection for the selected fourteen-pin package.
Leave open; do not connect to ground.
No internal connection for the selected fourteen-pin package.
Leave open; do not connect to ground.