Gas, humidity, pressure and temperature sensor

BME680 Reference Tables

Search the BME680 pin reference and manufacturer-referenced specification tables.

Selected packageLGA-8BME680
Physical connections8 pinsPackage-specific numbering
Reference collection7 tables48 parameters & pin functions

Pin reference

Signal names, electrical functions and connection guidance

LGA-8
Physical pin numbers8 pins

Scroll within the table to see all columns and rows.

BME680 pin functions and connections
PinSignalTypeFunction & connection
GNDReturnFirst ground contact.
Connection guidance

Join common ground with contact 7.

CSBInputActive-low SPI select and interface selection.
Connection guidance

For I²C, connect directly to VDDIO.

SDI / SDABidirectionalSPI input or I²C data.
Connection guidance

Connect to controller SDA with a VDDIO pullup for I²C.

SCK / SCLInputClock from the host.
Connection guidance

Connect to controller SCL with a VDDIO pullup for I²C.

SDO / ADDROutput / addressSPI output or I²C address selection.
Connection guidance

Ground selects 0x76; VDDIO selects 0x77.

Do not float in I²C; leave unconnected in three-wire SPI.

VDDIOSupplyLogic supply.
Connection guidance

Use 1.2–3.6 V with a 100 nF local bypass.

The example uses 3.3 V, not 5 V.

GNDReturnSecond ground contact.
Connection guidance

Join contact 1 and host ground.

VDDSupplySensor and heater supply.
Connection guidance

Use 1.71–3.6 V and a separate 100 nF bypass.

Allow the heater pulse current in the supply budget.

LGA-8 · Top view · clockwise numbering · Select a pin number to open its interactive pinout.

Supplies and interface

Bare IC; module regulators are separate

Manufacturer-referenced values8 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
VDD1.71–3.6 VSensor and heater supply
VDDIO1.2–3.6 VBus pullups use this logic rail
Sleep current0.15 µA typical; 1 µA maximumGas heater inactive
Startup2 ms maximumAfter the specified rail thresholds
Local bypass100 nF on each railPlace close to the package
I²C / SPI clockUp to 3.4 MHz / 10 MHzMeet the selected interface timing
I²C address0x76 or 0x77, seven-bitSelected by SDO low or high
I²C selectionCSB tied directly to VDDIOSDA3 and SCL4 need pullups

The example uses 3.3 V and 4.7 kΩ pullups on a short bus.

Environmental measurements

Manufacturer conditions apply

Manufacturer-referenced values8 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Humidity range0–100% RH, non-condensingFull accuracy range 10–90% RH, 0–65°C
Humidity accuracy±3% RH20–80% RH at 25°C, including hysteresis
Humidity response8 s typical to 63%Specified airflow and humidity step
Pressure range300–1100 hPaFull-accuracy temperature range 0–65°C
Typical absolute pressure error±0.6 hPa300–1100 hPa, 0–65°C
Typical relative pressure error±0.12 hPa700–1100 hPa, 25–40°C, constant humidity
Typical temperature error±0.5°C at 25°C; ±1.0°C over 0–65°CDie temperature includes PCB and self-heating effects
Operational temperature−40°C to +85°CNot the same as the full-accuracy range

Do not substitute BME280 or BME688 specifications.

Gas heater and measurement

Response depends on the operating profile

Manufacturer-referenced values8 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Gas-sensor principleHeated metal-oxide resistanceBroad response, not identification of a single gas
Example heater target300°C for 100 msManufacturer quick-start profile; this is hotplate temperature
Constant-heater current12 mA typical; 13 mA maximum320°C target, VDD ≤1.8 V, 25°C
Startup heater peak17 mA typical; 18 mA maximumWithin the first millisecond under stated conditions
Gas measurement operating RH10–95% RHSeparate from the humidity channel measurement range
Gas-valid flaggas_r_lsb 0x2B bit 5Reject an invalid gas conversion
Heater-stable flaggas_r_lsb 0x2B bit 4Check that the heater reached its target
Gas conversionADC count plus range and calibrationDo not display the raw count as ohms

Power averages depend on duty cycle; a low average does not remove the pulse-current requirement.

Forced-mode acquisition

I²C register addresses in hexadecimal

Manufacturer-referenced values9 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Chip ID / reset0xD0 → 0x61; write 0xB6 to 0xE0Read identification and calibration before sampling
ctrl_hum0x72 bits 2:0Humidity oversampling; write before ctrl_meas
ctrl_meas0x74Temperature bits 7:5; pressure bits 4:2; mode bits 1:0
config0x75IIR filter bits 4:2 and three-wire SPI bit 0
ctrl_gas_10x71Enable gas conversion and select heater profile
Heater resistance / durationres_heat_0 0x5A; gas_wait_0 0x64Heater resistance code depends on calibration and ambient temperature
100 ms duration examplegas_wait_0 = 0x59Duration is encoded; it is not a plain millisecond byte
Start measurementmode bits = 01One forced measurement followed by sleep
meas_status_00x1DNew data bit 7; gas measuring bit 6; measuring bit 5

Configure while idle; allow the complete temperature/pressure/humidity/heater sequence.

Calibration and air-quality output

Keep measured units distinct from derived estimates

Manufacturer-referenced values8 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Temperature compensationCalculate first with factory coefficientsProvides the intermediate used by other channels
Pressure and humidityUse the BME680 compensation formulasPreserve coefficient signs and packed humidity fields
Gas resistanceUse gas ADC, range and the specified correctionReport ohms or kΩ with heater conditions
Example pressure units100000 Pa / 100 = 1000 hPaIllustrative compensated result
Illustrative gas reading100000 Ω = 100 kΩThis value alone does not determine IAQ or ppm
BSEC IAQSoftware-derived index from 0 to 500Not a value directly read from a hardware register
IAQ accuracy status0 through 3Includes stabilization and calibration state
CO₂ interpretationNo direct CO₂ concentration measurementEquivalent values from software are estimates, not a selective CO₂ sensor

Do not infer a specific contaminant concentration from one gas-resistance reading.

Contacts and mounting

Clockwise numbering in top view

Manufacturer-referenced values7 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Ground / interface select1 GND, 2 CSBCSB connects to VDDIO for I²C
Clock / data3 SDI, 4 SCK, 5 SDOSDO sets the I²C address
Logic / ground / sensor rail6 VDDIO, 7 GND, 8 VDDConnect both grounds and bypass both rails
Body dimensions3.0 × 3.0 × 0.93 mm typical1.00 mm maximum height
Copper landsEight 0.40 mm squares0.80 mm pitch; 2.40 mm row centers
Mask openings in Bosch drawing0.60 mm squaresDistinct from the 0.40 mm exposed copper lands
VentKeep free of coating, flux and contaminationAllow air exchange and follow handling instructions

The authored KiCad file contains copper and paste lands; apply the target board’s solder-mask process.

Read each value with its conditions

Typical values describe the stated test conditions. Absolute maximum ratings are stress limits, not operating targets.

Bosch Sensortec · BST-BME680-DS001-09 · February 2024 · Revision 1.9
Official PDF datasheet