BME680 Specifications
Review BME680 electrical specifications, operating conditions and package details.
Key specifications
Humidity, pressure and temperature use individual compensation. The gas channel reports a resistance dependent on exposure, heater conditions and sensor history. A BSEC air-quality index is a separate calculated output.
Package details
BME680 · LGA-8
| Property | Details |
|---|---|
| Manufacturer | Bosch Sensortec |
| Part number | BME680 |
| Package | LGA-8 |
| Connections | 8 pins |
| Mounting | SMD |
| Lead pitch | 0.80 mm |
| Package code | LGA-8 |
| Thermal reference | −40°C to +85°C operational |
Supplies and interface
Bare IC; module regulators are separate
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VDD | 1.71–3.6 V | Sensor and heater supply |
| VDDIO | 1.2–3.6 V | Bus pullups use this logic rail |
| Sleep current | 0.15 µA typical; 1 µA maximum | Gas heater inactive |
| Startup | 2 ms maximum | After the specified rail thresholds |
| Local bypass | 100 nF on each rail | Place close to the package |
| I²C / SPI clock | Up to 3.4 MHz / 10 MHz | Meet the selected interface timing |
| I²C address | 0x76 or 0x77, seven-bit | Selected by SDO low or high |
| I²C selection | CSB tied directly to VDDIO | SDA3 and SCL4 need pullups |
No specifications match. Try a parameter name or a unit.
The example uses 3.3 V and 4.7 kΩ pullups on a short bus.
Environmental measurements
Manufacturer conditions apply
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Humidity range | 0–100% RH, non-condensing | Full accuracy range 10–90% RH, 0–65°C |
| Humidity accuracy | ±3% RH | 20–80% RH at 25°C, including hysteresis |
| Humidity response | 8 s typical to 63% | Specified airflow and humidity step |
| Pressure range | 300–1100 hPa | Full-accuracy temperature range 0–65°C |
| Typical absolute pressure error | ±0.6 hPa | 300–1100 hPa, 0–65°C |
| Typical relative pressure error | ±0.12 hPa | 700–1100 hPa, 25–40°C, constant humidity |
| Typical temperature error | ±0.5°C at 25°C; ±1.0°C over 0–65°C | Die temperature includes PCB and self-heating effects |
| Operational temperature | −40°C to +85°C | Not the same as the full-accuracy range |
No specifications match. Try a parameter name or a unit.
Do not substitute BME280 or BME688 specifications.
Gas heater and measurement
Response depends on the operating profile
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Gas-sensor principle | Heated metal-oxide resistance | Broad response, not identification of a single gas |
| Example heater target | 300°C for 100 ms | Manufacturer quick-start profile; this is hotplate temperature |
| Constant-heater current | 12 mA typical; 13 mA maximum | 320°C target, VDD ≤1.8 V, 25°C |
| Startup heater peak | 17 mA typical; 18 mA maximum | Within the first millisecond under stated conditions |
| Gas measurement operating RH | 10–95% RH | Separate from the humidity channel measurement range |
| Gas-valid flag | gas_r_lsb 0x2B bit 5 | Reject an invalid gas conversion |
| Heater-stable flag | gas_r_lsb 0x2B bit 4 | Check that the heater reached its target |
| Gas conversion | ADC count plus range and calibration | Do not display the raw count as ohms |
No specifications match. Try a parameter name or a unit.
Power averages depend on duty cycle; a low average does not remove the pulse-current requirement.
Forced-mode acquisition
I²C register addresses in hexadecimal
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Chip ID / reset | 0xD0 → 0x61; write 0xB6 to 0xE0 | Read identification and calibration before sampling |
| ctrl_hum | 0x72 bits 2:0 | Humidity oversampling; write before ctrl_meas |
| ctrl_meas | 0x74 | Temperature bits 7:5; pressure bits 4:2; mode bits 1:0 |
| config | 0x75 | IIR filter bits 4:2 and three-wire SPI bit 0 |
| ctrl_gas_1 | 0x71 | Enable gas conversion and select heater profile |
| Heater resistance / duration | res_heat_0 0x5A; gas_wait_0 0x64 | Heater resistance code depends on calibration and ambient temperature |
| 100 ms duration example | gas_wait_0 = 0x59 | Duration is encoded; it is not a plain millisecond byte |
| Start measurement | mode bits = 01 | One forced measurement followed by sleep |
| meas_status_0 | 0x1D | New data bit 7; gas measuring bit 6; measuring bit 5 |
No specifications match. Try a parameter name or a unit.
Configure while idle; allow the complete temperature/pressure/humidity/heater sequence.
Calibration and air-quality output
Keep measured units distinct from derived estimates
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Temperature compensation | Calculate first with factory coefficients | Provides the intermediate used by other channels |
| Pressure and humidity | Use the BME680 compensation formulas | Preserve coefficient signs and packed humidity fields |
| Gas resistance | Use gas ADC, range and the specified correction | Report ohms or kΩ with heater conditions |
| Example pressure units | 100000 Pa / 100 = 1000 hPa | Illustrative compensated result |
| Illustrative gas reading | 100000 Ω = 100 kΩ | This value alone does not determine IAQ or ppm |
| BSEC IAQ | Software-derived index from 0 to 500 | Not a value directly read from a hardware register |
| IAQ accuracy status | 0 through 3 | Includes stabilization and calibration state |
| CO₂ interpretation | No direct CO₂ concentration measurement | Equivalent values from software are estimates, not a selective CO₂ sensor |
No specifications match. Try a parameter name or a unit.
Do not infer a specific contaminant concentration from one gas-resistance reading.
Contacts and mounting
Clockwise numbering in top view
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Ground / interface select | 1 GND, 2 CSB | CSB connects to VDDIO for I²C |
| Clock / data | 3 SDI, 4 SCK, 5 SDO | SDO sets the I²C address |
| Logic / ground / sensor rail | 6 VDDIO, 7 GND, 8 VDD | Connect both grounds and bypass both rails |
| Body dimensions | 3.0 × 3.0 × 0.93 mm typical | 1.00 mm maximum height |
| Copper lands | Eight 0.40 mm squares | 0.80 mm pitch; 2.40 mm row centers |
| Mask openings in Bosch drawing | 0.60 mm squares | Distinct from the 0.40 mm exposed copper lands |
| Vent | Keep free of coating, flux and contamination | Allow air exchange and follow handling instructions |
No specifications match. Try a parameter name or a unit.
The authored KiCad file contains copper and paste lands; apply the target board’s solder-mask process.
Connections by function
Select a pin for its function, connection guidance and electrical notes.