OFFSET1
Function
One end of the optional offset-null network.
How to connect
Leave open in the basic example.
Electrical note
Use the manufacturer trim circuit when offset adjustment is required.
Explore LM741 pins, signal names, electrical functions and connection guidance for each package.
Select a pin to explore its connection
Click a lead or use the arrow keys. Top view
One end of the optional offset-null network.
Leave open in the basic example.
Use the manufacturer trim circuit when offset adjustment is required.
Negative feedback input.
Connect to the 90 kΩ / 10 kΩ feedback junction.
Positive signal input.
Apply the 0.20 V input signal relative to the supply midpoint.
Negative power rail.
Connect to −15 V; bypass locally to the 0 V midpoint.
This is not ground in the illustrated split-supply circuit.
Other end of the optional offset-null network.
Leave open in the basic example.
Amplified output signal.
Connect the 90 kΩ feedback resistor and a high-impedance meter.
Output needs headroom from both supply rails.
Positive power rail.
Connect to +15 V; bypass locally to the 0 V midpoint.
No electrical connection is specified for this contact.
Leave unconnected.