VOUT
Function
Regulated output.
How to connect
Connect output capacitors and the feedback divider.
Explore TPS63000 pins, signal names, electrical functions and connection guidance for each package.
Select a pin to explore its connection
Click a lead or use the arrow keys. Top view · ten edge contacts and exposed pad 11
Regulated output.
Connect output capacitors and the feedback divider.
Inductor switching node.
Connect one end of the 2.2 µH inductor; other end to L1 pin 4.
Power ground.
Return the high-current input/output capacitor loops here.
Inductor switching node.
Connect the other end of the inductor from L2 pin 2.
Power supply input.
Bypass to PGND locally with 10 µF in the example.
Enable input.
Tie high to enable; low disables. Do not leave floating.
Mode / clock input.
Low permits power save, high forces fixed-frequency operation; also accepts a synchronization clock.
Control supply input.
Use the example 100 Ω from VIN and 0.1 µF to GND filter.
Control ground.
Join power ground at a quiet local connection.
Output feedback.
Connect the junction of 1.12 MΩ from VOUT and 200 kΩ to GND.
Exposed thermal pad.
Solder to PGND copper; underside pad is numbered 11 in this footprint.