IP+
Function
First positive-side contact of the internal copper current path.
How to connect
Join pin 2 and the source side of the measured circuit.
Electrical note
Use both contacts and adequate copper. This is not a logic pin.
Explore ACS712 pins, signal names, electrical functions and connection guidance for each package.
Select a pin to explore its connection
Click a lead or use the arrow keys. Top view
First positive-side contact of the internal copper current path.
Join pin 2 and the source side of the measured circuit.
Use both contacts and adequate copper. This is not a logic pin.
Second positive-side contact; internally joined with pin 1.
Join pin 1 with a suitably wide copper area.
First negative-side contact of the sampled current path.
Join pin 4 and the load side of the circuit.
Second negative-side contact; internally joined with pin 3.
Join pin 3; positive current flows from pins 1/2 to 3/4.
Reference for the sensor supply and output.
Connect to the ADC/controller ground.
The Hall signal side is electrically isolated from the primary conductor inside the IC.
External capacitor to ground forms a low-pass with the internal filter resistance.
Use 1 nF to GND in the example.
Larger capacitance lowers bandwidth and noise; it does not remove offset error.
Ratiometric voltage around VCC/2 at zero current.
Connect to a high-impedance ADC with a compatible input range.
The example uses the ±5 A variant, 185 mV/A typical at 5 V.
Powers the Hall electronics.
Use regulated 5 V with 100 nF to GND.
Operating supply 4.5–5.5 V; not a 3.3 V supply device.