ADXL345 Specifications
Review ADXL345 electrical specifications, operating conditions and package details.
Key specifications
A moving MEMS structure changes capacitance. Conversion and filtering produce three signed values. A stationary device still reports gravity along its sensitive axes.
Package details
ADXL345 · LGA-14
| Property | Details |
|---|---|
| Manufacturer | Analog Devices |
| Part number | ADXL345 |
| Package | LGA-14 |
| Connections | 14 pins |
| Mounting | SMD |
| Lead pitch | 0.80 mm |
| Package code | CC-14-1 |
| Thermal reference | −40 to +85°C |
Power and operating limits
Recommended operation, not survival ratings
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VS | 2.0–3.6 V | 2.5 V used for the reference example |
| VDD I/O | 1.7 V to VS | Use compatible host logic and pull-ups |
| Temperature | −40 to +85°C | Operating range |
| Measurement current | 140 µA typical | Normal mode, ODR ≥100 Hz, specified conditions |
| Standby current | 0.1 µA typical | Not the current while measuring |
| Low-power mode | As low as 23 µA typical | Specific low-power rate setting; not all modes |
| Shock survival | 10,000 g | Survival rating, not an acceleration measurement range |
No specifications match. Try a parameter name or a unit.
Keep supply-domain sequencing and absolute maximum limits in mind when interfacing a separately powered controller.
Range, resolution and scale
Full-resolution and fixed-resolution modes differ
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Full resolution | About 3.9 mg/LSB | Nominal 256 LSB/g across selectable ranges |
| ±2 g | 10 useful bits | Full-resolution or fixed 10-bit mode |
| ±4 g | 11 useful bits in full-resolution mode | Fixed 10-bit scale is 128 LSB/g nominal |
| ±8 g | 12 useful bits in full-resolution mode | Fixed 10-bit scale is 64 LSB/g nominal |
| ±16 g | 13 useful bits in full-resolution mode | Fixed 10-bit scale is 32 LSB/g nominal |
| Result representation | Signed two’s complement in a 16-bit word | Default right justification in this example |
| Sensitivity specification | 230–282 LSB/g at ±2 g | Typical 256, stated 2.5 V test conditions |
No specifications match. Try a parameter name or a unit.
Do not confuse the 16-bit register container with 16-bit measurement resolution.
Core register map
An initial configuration and coherent burst read
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| 0x00 · DEVID | 0xE5 | Read-only device identification |
| 0x2C · BW_RATE | 0x0A | 100 Hz output, normal power |
| 0x31 · DATA_FORMAT | 0x08 | Full resolution, ±2 g, right justified |
| 0x2D · POWER_CTL | 0x08 | Measurement enabled |
| 0x32–0x37 · axis data | X0, X1, Y0, Y1, Z0, Z1 | Low byte first for each signed axis |
| 0x2E / 0x2F / 0x30 | INT_ENABLE / INT_MAP / INT_SOURCE | Configure and identify interrupts |
| 0x38 / 0x39 | FIFO_CTL / FIFO_STATUS | Configure buffering and read occupancy |
No specifications match. Try a parameter name or a unit.
Set format/rate before enabling measurement; use the manufacturer’s detailed register descriptions for other features.
I²C, SPI and buffering
Address and transaction rules
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| I²C selection | CS tied high | Never leave CS floating |
| I²C address | 0x53 with ALTADDR low; 0x1D high | Seven-bit address |
| I²C clock | Up to 400 kHz | At 100 kHz, keep ODR at 200 Hz or lower; at 400 kHz, 800 Hz or lower |
| SPI | 3-wire or 4-wire, up to 5 MHz | MSB first; clock polarity high and sample rising |
| FIFO | 32 samples; bypass, FIFO, stream, trigger modes | Read all axis bytes together |
| Interrupt routing | INT1 or INT2 | Data-ready, watermark, overrun, tap, activity and free-fall |
| Fresh read | Wait for data-ready | Avoid reading faster and treating repeats as new motion |
No specifications match. Try a parameter name or a unit.
For 1600/3200 Hz output the data format and interface timing need particular attention; consult the reference.
2.5 V I²C wiring example
Bare IC with deliberate reserved-pin handling
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VS6 | 2.5 V with 1 µF tantalum | Place bypass at the terminal |
| VDD I/O1 | 2.5 V with 100 nF ceramic | Separate local bypass |
| GND2,4,5 | Common ground plane | Low-impedance return |
| CS7 | VDD I/O | Select I²C |
| ALTADDR12 | GND | Select 0x53 |
| SDA13 / SCL14 | Host I²C with 4.7 kΩ pull-ups | Pull up to VDD I/O |
| Reserved3 / Reserved11 | VS / GND in this example | Manufacturer also permits leaving these open |
| NC10 / INT1 / INT2 | Open if unused | NC is not a ground pin |
No specifications match. Try a parameter name or a unit.
A 5 V microcontroller needs suitable level translation. The bare sensor is not a 5 V module.
Signed readings and calibration
Illustrative static examples at nominal sensitivity
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| 00 01, low byte first | 0x0100 = +256 | Approximately +1 g |
| 80 FF, low byte first | 0xFF80 = −128 | Approximately −0.5 g |
| Acceleration | g ≈ signed_count / 256 | Nominal full-resolution scale |
| Stationary top up | X≈0, Y≈0, Z≈+1 g | Offset and alignment affect real readings |
| Calibration | Measure offsets and scale per axis | Separate static gravity from dynamic acceleration |
| Operation at 3.3 V | Sensitivity and offset shift | Do not silently substitute the 2.5 V nominal calibration |
No specifications match. Try a parameter name or a unit.
Illustrations are calculations rather than live measurements. The datasheet describes voltage-dependent scale changes.
Mechanical and layout guidance
Mounting quality matters
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Package | 14-terminal LGA, 3 × 5 × 1 mm | CC-14-1 |
| Side pitch | 0.80 mm | Six pads on each long side, one at each end |
| Pin numbering | 1–6 left, 7 bottom, 8–13 right, 14 top | Top view |
| Contacts | Au over Ni underside lands | The package has no long projecting DIP leads |
| Placement | Near a rigid PCB mounting point | Avoid unsupported vibrating PCB areas |
| Filtering | Match bandwidth to the measurement | Bandwidth is nominally half the output data rate |
No specifications match. Try a parameter name or a unit.
Do not use survival shock ratings or cartoon motion as a substitute for the measurement limits.
Connections by function
Select a pin for its function, connection guidance and electrical notes.