Skip to datasheet
Digital barometric pressure sensor

BMP388 Specifications

Review BMP388 electrical specifications, operating conditions and package details.

Key specifications

Read the sensor’s own trim coefficients, acquire a consistent pressure/temperature burst and apply the BMP388 compensation equations. A raw ADC count is not a value in pascals.

Pressure range300–1250 hPa
Sensor supply1.65–3.6 V · VDD
Typical absolute error±0.5 hPa · specified conditions
Metal-lid body2 × 2 mm

Operating profile

Supply, signals and operating conditions

BMP388 operating profile
ParameterValueConditions / notes
Selected packageLGA-1010 contacts · 0.75 mm typical height
Operating temperature−40 to +85°CFull accuracy conditions are narrower
Host interfaceI²C / SPITwo I²C addresses; three- or four-wire SPI
Use these values with the stated grade and test conditions.

Package details

BMP388 · LGA-10

Selected package
Selected BMP388 physical package
PropertyDetails
ManufacturerBosch Sensortec
Part numberBMP388
PackageLGA-10
Connections10 pins
MountingSMD
Lead pitch0.50 mm
Package codeLGA-10
Thermal reference−40°C to +85°C operational

Supplies and interface

Bare-sensor operating limits

Scroll sideways to see all columns.

ParameterValueConditions / notes
VDD sensor rail1.65–3.6 VMaximum specified supply ripple 50 mV peak-to-peak
VDDIO logic rail1.2–3.6 VPull up the bus to this rail
Sleep current2 µA typicalVDD = VDDIO, 1.8–3.6 V
Pressure-conversion current700 µA typical; 800 µA maximumNot the low-rate average current
Startup2 ms maximumAfter both supplies meet the stated thresholds
I²C / SPI clocksUp to 3.4 MHz / 10 MHzObserve the timing conditions; example uses ordinary I²C
Bypass / pullups100 nF per rail; 4.7 kΩ example pullupsChoose bus resistors for capacitance and speed

Operating limits are not absolute maximum stress ratings.

Pressure and temperature

Accuracy depends on conditions

Scroll sideways to see all columns.

ParameterValueConditions / notes
Pressure range300–1250 hPaSee full-accuracy conditions
Typical absolute pressure error±0.50 hPa300–1100 hPa, −20°C to +65°C
Typical relative pressure error±0.08 hPa900–1100 hPa, 25°C to 40°C; per 10 kPa steps
Temperature operating range−40°C to +85°CFull-accuracy temperature range 0°C to 65°C
Typical temperature error±0.3°C at 25°C±0.50°C over 0°C to 65°C
Temperature meaningSensor/board temperatureSelf-heating and PCB heat can raise it above ambient
Maximum sample rate200 HzOnly with settings whose conversion time fits
Typical pressure noise1.2 Pa full bandwidth; 0.03 Pa filteredHighest resolution; the lowest noise is not available at every bandwidth

Noise, resolution and absolute accuracy are different quantities.

Protocol and pins

I²C example at seven-bit address 0x76

Scroll sideways to see all columns.

ParameterValueConditions / notes
I²C clock / data2 SCK / 4 SDIUse these as SCL / SDA
Address selection5 SDO low → 0x76; high → 0x77Do not leave floating
I²C protocol selection6 CSB held high at power-onPulling it low locks SPI until the next power-on reset
SPI connections2 clock, 4 MOSI, 5 MISO, 6 CSBModes 0 or 3; SDO unconnected for three-wire mode
SPI read framingRead bit in command, then one dummy byteFollowing bytes are register data
Interrupt7 INTOptional data-ready or FIFO notification
Ground contacts3, 8 and 9 VSSConnect all three
Supply contacts1 VDDIO and 10 VDDBypass both locally

Package orientation matters: the top-view pin-one marker is upper right.

Measurement control

Register addresses are hexadecimal

Scroll sideways to see all columns.

ParameterValueConditions / notes
CHIP_ID / ERR_REG / STATUS0x00 / 0x02 / 0x03Expected ID 0x50; check errors and data-ready flags
Pressure and temperature burst0x04–0x09Pressure first; each unsigned 24-bit word is least-significant byte first
PWR_CTRL0x1BPressure enable bit 0, temperature bit 1, mode bits 5:4
OSR0x1CPressure bits 2:0; temperature bits 5:3; ×1 to ×32
ODR0x1DRate = 200 / 2^odr_sel Hz; valid selection 0–17
CONFIG0x1FIIR coefficient in bits 3:1; bypass through 127
CMD0x7E0xB6 soft reset; 0xB0 FIFO flush
FIFO capacity512 bytesParse headers and service before overflow

Do not configure a data rate faster than the selected conversion can complete.

Compensation and engineering units

Use the individual sensor coefficients

Scroll sideways to see all columns.

ParameterValueConditions / notes
Trim storage21 bytes from 0x31–0x45T1–T3 and P1–P11; preserve signedness
Unsigned coefficientsT1, T2, P5, P6 are 16-bitOther coefficient widths/signs follow the manufacturer table
Temperature firstCompute the intermediate linearized temperaturePressure compensation depends on it
Pressure nextApply the calibrated polynomial to the raw pressureUse the Bosch BMP3 driver or the datasheet algorithm
Pascals to hectopascals101325 Pa / 100 = 1013.25 hPaIllustrative compensated value, not a raw register example
AltitudeRequires a reference pressure and atmosphere modelWeather changes can mimic an altitude change
ConsistencyRead all six data bytes in one burstPrevents mixing bytes from different conversions

BMP280 and BMP388 calibration layouts and compensation algorithms are different.

Package and layout

Bosch Figure 26 land dimensions

Scroll sideways to see all columns.

ParameterValueConditions / notes
Metal-lid LGA2.0 × 2.0 × 0.75 mm typical0.8 mm maximum height
Contacts10; no center exposed padTop-view map is not the bottom-view drawing
Side lands0.275 × 0.250 mm0.5 mm pitch; 1.525 mm between row centers
Top and bottom lands0.250 × 0.275 mm0.5 mm between contact centers
Air portKeep open and uncontaminatedNo conformal coating over the sensing hole
LifecycleReference for BMP388 designsBosch recommends BMP390 for new designs

The original KiCad land pattern needs the normal manufacturing review for the target PCB process.

Connections by function

Select a pin for its function, connection guidance and electrical notes.

Supply2 pins

Clock1 pin

Ground3 pins

Serial data2 pins

Protocol selection1 pin

Interrupt1 pin

Read the conditions with every value

Typical values describe stated test conditions. Absolute maximum ratings are stress limits, not operating targets.

Official PDF datasheet

Component view