BMP388 Specifications
Review BMP388 electrical specifications, operating conditions and package details.
Key specifications
Read the sensor’s own trim coefficients, acquire a consistent pressure/temperature burst and apply the BMP388 compensation equations. A raw ADC count is not a value in pascals.
Package details
BMP388 · LGA-10
| Property | Details |
|---|---|
| Manufacturer | Bosch Sensortec |
| Part number | BMP388 |
| Package | LGA-10 |
| Connections | 10 pins |
| Mounting | SMD |
| Lead pitch | 0.50 mm |
| Package code | LGA-10 |
| Thermal reference | −40°C to +85°C operational |
Supplies and interface
Bare-sensor operating limits
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| VDD sensor rail | 1.65–3.6 V | Maximum specified supply ripple 50 mV peak-to-peak |
| VDDIO logic rail | 1.2–3.6 V | Pull up the bus to this rail |
| Sleep current | 2 µA typical | VDD = VDDIO, 1.8–3.6 V |
| Pressure-conversion current | 700 µA typical; 800 µA maximum | Not the low-rate average current |
| Startup | 2 ms maximum | After both supplies meet the stated thresholds |
| I²C / SPI clocks | Up to 3.4 MHz / 10 MHz | Observe the timing conditions; example uses ordinary I²C |
| Bypass / pullups | 100 nF per rail; 4.7 kΩ example pullups | Choose bus resistors for capacitance and speed |
No specifications match. Try a parameter name or a unit.
Operating limits are not absolute maximum stress ratings.
Pressure and temperature
Accuracy depends on conditions
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Pressure range | 300–1250 hPa | See full-accuracy conditions |
| Typical absolute pressure error | ±0.50 hPa | 300–1100 hPa, −20°C to +65°C |
| Typical relative pressure error | ±0.08 hPa | 900–1100 hPa, 25°C to 40°C; per 10 kPa steps |
| Temperature operating range | −40°C to +85°C | Full-accuracy temperature range 0°C to 65°C |
| Typical temperature error | ±0.3°C at 25°C | ±0.50°C over 0°C to 65°C |
| Temperature meaning | Sensor/board temperature | Self-heating and PCB heat can raise it above ambient |
| Maximum sample rate | 200 Hz | Only with settings whose conversion time fits |
| Typical pressure noise | 1.2 Pa full bandwidth; 0.03 Pa filtered | Highest resolution; the lowest noise is not available at every bandwidth |
No specifications match. Try a parameter name or a unit.
Noise, resolution and absolute accuracy are different quantities.
Protocol and pins
I²C example at seven-bit address 0x76
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| I²C clock / data | 2 SCK / 4 SDI | Use these as SCL / SDA |
| Address selection | 5 SDO low → 0x76; high → 0x77 | Do not leave floating |
| I²C protocol selection | 6 CSB held high at power-on | Pulling it low locks SPI until the next power-on reset |
| SPI connections | 2 clock, 4 MOSI, 5 MISO, 6 CSB | Modes 0 or 3; SDO unconnected for three-wire mode |
| SPI read framing | Read bit in command, then one dummy byte | Following bytes are register data |
| Interrupt | 7 INT | Optional data-ready or FIFO notification |
| Ground contacts | 3, 8 and 9 VSS | Connect all three |
| Supply contacts | 1 VDDIO and 10 VDD | Bypass both locally |
No specifications match. Try a parameter name or a unit.
Package orientation matters: the top-view pin-one marker is upper right.
Measurement control
Register addresses are hexadecimal
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| CHIP_ID / ERR_REG / STATUS | 0x00 / 0x02 / 0x03 | Expected ID 0x50; check errors and data-ready flags |
| Pressure and temperature burst | 0x04–0x09 | Pressure first; each unsigned 24-bit word is least-significant byte first |
| PWR_CTRL | 0x1B | Pressure enable bit 0, temperature bit 1, mode bits 5:4 |
| OSR | 0x1C | Pressure bits 2:0; temperature bits 5:3; ×1 to ×32 |
| ODR | 0x1D | Rate = 200 / 2^odr_sel Hz; valid selection 0–17 |
| CONFIG | 0x1F | IIR coefficient in bits 3:1; bypass through 127 |
| CMD | 0x7E | 0xB6 soft reset; 0xB0 FIFO flush |
| FIFO capacity | 512 bytes | Parse headers and service before overflow |
No specifications match. Try a parameter name or a unit.
Do not configure a data rate faster than the selected conversion can complete.
Compensation and engineering units
Use the individual sensor coefficients
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Trim storage | 21 bytes from 0x31–0x45 | T1–T3 and P1–P11; preserve signedness |
| Unsigned coefficients | T1, T2, P5, P6 are 16-bit | Other coefficient widths/signs follow the manufacturer table |
| Temperature first | Compute the intermediate linearized temperature | Pressure compensation depends on it |
| Pressure next | Apply the calibrated polynomial to the raw pressure | Use the Bosch BMP3 driver or the datasheet algorithm |
| Pascals to hectopascals | 101325 Pa / 100 = 1013.25 hPa | Illustrative compensated value, not a raw register example |
| Altitude | Requires a reference pressure and atmosphere model | Weather changes can mimic an altitude change |
| Consistency | Read all six data bytes in one burst | Prevents mixing bytes from different conversions |
No specifications match. Try a parameter name or a unit.
BMP280 and BMP388 calibration layouts and compensation algorithms are different.
Package and layout
Bosch Figure 26 land dimensions
Scroll sideways to see all columns.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Metal-lid LGA | 2.0 × 2.0 × 0.75 mm typical | 0.8 mm maximum height |
| Contacts | 10; no center exposed pad | Top-view map is not the bottom-view drawing |
| Side lands | 0.275 × 0.250 mm | 0.5 mm pitch; 1.525 mm between row centers |
| Top and bottom lands | 0.250 × 0.275 mm | 0.5 mm between contact centers |
| Air port | Keep open and uncontaminated | No conformal coating over the sensing hole |
| Lifecycle | Reference for BMP388 designs | Bosch recommends BMP390 for new designs |
No specifications match. Try a parameter name or a unit.
The original KiCad land pattern needs the normal manufacturing review for the target PCB process.
Connections by function
Select a pin for its function, connection guidance and electrical notes.