Digital temperature and humidity sensor

DHT11 Reference Tables

Search the DHT11 pin reference and manufacturer-referenced specification tables.

Selected packageVented SIP-4DHT11
Physical connections4 pinsPackage-specific numbering
Reference collection7 tables45 parameters & pin functions

Pin reference

Signal names, electrical functions and connection guidance

Vented SIP-4
Physical pin numbers4 pins

Scroll within the table to see all columns and rows.

DHT11 pin functions and connections
PinSignalTypeFunction & connection
VCCSupplyPositive supply input.
Connection guidance

Connect to 3.3–5.5 V. The example uses 5 V and a local 100 nF bypass.

Use a controller whose input tolerates the chosen data pullup voltage.

SDABidirectional dataSingle data line carries the start pulse, response and 40-bit frame.
Connection guidance

Use an open-drain or switchable input/output GPIO and an external pullup.

This is the DHT pulse-width protocol, not I²C or Dallas 1-Wire.

NCNo connectionUnused physical lead.
Connection guidance

Leave unconnected.

GNDGroundSupply and data reference.
Connection guidance

Connect to the controller ground.

Vented SIP-4 · Front view · vent face toward you · leads down · Select a pin number to open its interactive pinout.

Supply and sampling

December 2022 manufacturer revision

Manufacturer-referenced values7 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Supply3.3–5.5 V5 V nominal in the manufacturer table
Startup waitAt least 2 sDo not request a reading during initialization
Sampling intervalAt least 2 sAlso applies when requesting a fresh second result
Sleep / measurement current60 µA / 1000 µA typicalVCC=5 V and 25°C
Typical pullup4.7 kΩShort local connection; adjust for line capacitance
Example bypass100 nFLocal VCC-to-GND decoupling
3.3 V wiring adviceKeep cable within 1 mManufacturer recommendation to limit supply drop

The wire carries timed pulses, not an addressable multidrop protocol.

Temperature and humidity

Reference conditions and range qualifications

Manufacturer-referenced values9 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Humidity measurement envelope5–95%RHNormal recommended scope is narrower and temperature-dependent
Normal humidity scope8–85%RH headlineFollow the working-conditions curve, especially near temperature extremes
Humidity error±5%RH typical25°C, VCC=5 V, non-condensing; excludes hysteresis/nonlinearity
Humidity repeatability / hysteresis±1%RH / ±0.3%RH typicalReference conditions
Humidity responseLess than 6 s typical63% response at 25°C and 1 m/s airflow
Temperature range−20°C to +60°CSelected manual revision
Temperature error / repeatability±2°C / ±1°C typicalNot a claim of decimal-byte accuracy
Temperature response5–30 sDepends on airflow and thermal coupling
Long-term driftLess than 0.5%RH/year and 0.5°C/year typicalReference conditions

Keep the sensor away from heat sources and contaminants; avoid condensation.

Single-wire timing

Use the min/max windows from this revision

Manufacturer-referenced values8 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Host start LOW18–30 ms20 ms typical
Host release interval10–35 µs13 µs typical
Sensor response LOW78–88 µs83 µs typical
Sensor response HIGH80–92 µs87 µs typical
Each bit LOW50–58 µs54 µs typical
Zero-bit HIGH23–27 µs24 µs typical
One-bit HIGH68–74 µs71 µs typical
Release after frame52–56 µs LOWThen sensor releases SDA

Use bounded receive timeouts. Interrupt latency must not obscure the short pulse windows.

Five-byte measurement frame

40 bits · MSB first · DHT11 format

Manufacturer-referenced values7 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Byte 0Humidity integer52 decimal for 52.x%RH
Byte 1Humidity decimal portionFollow this device revision; do not combine as an AM2302 16-bit value
Byte 2Temperature integer magnitude25 decimal for +25.x°C
Byte 3Sign and temperature decimal portionBit 7 selects negative; lower bits carry fractional data
Byte 4Sum of bytes 0–3 modulo 256Reject the frame if the received check byte differs
Example frame34 00 19 00 4D hex52%RH, +25°C; 0x34+0x00+0x19+0x00=0x4D
Prior measurementReturned before a new conversionFor a fresh second result, keep the ≥2 s interval

Do not interpret DHT11 bytes with the AM2302 sign/magnitude 16-bit format.

Four leads, three connections

Front vent face toward you; leads down

Manufacturer-referenced values7 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Pin 1 · VCC5 V in this exampleSensor and controller use the same rail
Pin 2 · SDAController bidirectional GPIO4.7 kΩ pullup to 5 V
Pin 3 · NCLeave openDo not ground this contact
Pin 4 · GNDCommon controller returnKeep motor currents away from the signal ground
Controller portOpen drain / switchable inputRelease the bus after the start pulse
3.3 V MCU with 5 V sensorCheck input tolerance or level-shiftDo not assume its input is 5 V tolerant
Communication topologyOne sensor per GPIONo device address is present in the DHT frame

The bare sensor and a breakout board can have different connector orders.

Enclosure and installation

Original package and footprint views

Manufacturer-referenced values7 parameters

Scroll within the table to see all columns and rows.

ParameterValueConditions / notes
Blue enclosure12.50×16.00×6.00 mmManufacturer drawing; nominal dimensions
Lead pitch2.54 mmFour straight leads; 7.62 mm outer span
Exposed lead length7.20±0.50 mmDrawing value
Lead section0.50×0.30 mm nominalCheck finished-hole allowance
Original footprint1.80 mm pads; 1.00 mm drillsUpright SIP-4; review assembly clearances
Air openingsKeep unobstructedEnclosures and absorbent materials can slow response
SMD packageNot shown for this sensorDo not substitute a generic IC package

The 3D view is an original nominal enclosure illustration; the KiCad file is a reviewed authored footprint.

Read each value with its conditions

Typical values describe the stated test conditions. Absolute maximum ratings are stress limits, not operating targets.

ASAIR / Aosong · DHT11 manual · December 2022
Official PDF datasheet