Skip to datasheet
Digital temperature and humidity sensor

DHT11 Specifications

Review DHT11 electrical specifications, operating conditions and package details.

Key specifications

Each bit starts LOW. A short HIGH interval represents zero; a longer HIGH interval represents one. The last byte checks the sum of the four measurement bytes.

Humidity envelope5–95 %RH · current manual
Temperature−20–60 °C
Supply3.3–5.5 V
Read interval≥2 seconds

Operating profile

Supply, signals and operating conditions

DHT11 operating profile
ParameterValueConditions / notes
Selected packageVented SIP-44 physical leads · 3 connections
Typical temperature error±2°CNon-condensing reference conditions
Typical humidity error±5%RHAt 25°C and 5 V; excludes hysteresis/nonlinearity
Use these values with the stated grade and test conditions.

Package details

DHT11 · Vented SIP-4

Selected package
Selected DHT11 physical package
PropertyDetails
ManufacturerASAIR / Aosong
Part numberDHT11
PackageVented SIP-4
Connections4 pins
MountingThrough-hole
Lead pitch2.54 mm
Package codeSIP-4
Thermal reference−20°C to +60°C · December 2022 revision

Supply and sampling

December 2022 manufacturer revision

Scroll sideways to see all columns.

ParameterValueConditions / notes
Supply3.3–5.5 V5 V nominal in the manufacturer table
Startup waitAt least 2 sDo not request a reading during initialization
Sampling intervalAt least 2 sAlso applies when requesting a fresh second result
Sleep / measurement current60 µA / 1000 µA typicalVCC=5 V and 25°C
Typical pullup4.7 kΩShort local connection; adjust for line capacitance
Example bypass100 nFLocal VCC-to-GND decoupling
3.3 V wiring adviceKeep cable within 1 mManufacturer recommendation to limit supply drop

The wire carries timed pulses, not an addressable multidrop protocol.

Temperature and humidity

Reference conditions and range qualifications

Scroll sideways to see all columns.

ParameterValueConditions / notes
Humidity measurement envelope5–95%RHNormal recommended scope is narrower and temperature-dependent
Normal humidity scope8–85%RH headlineFollow the working-conditions curve, especially near temperature extremes
Humidity error±5%RH typical25°C, VCC=5 V, non-condensing; excludes hysteresis/nonlinearity
Humidity repeatability / hysteresis±1%RH / ±0.3%RH typicalReference conditions
Humidity responseLess than 6 s typical63% response at 25°C and 1 m/s airflow
Temperature range−20°C to +60°CSelected manual revision
Temperature error / repeatability±2°C / ±1°C typicalNot a claim of decimal-byte accuracy
Temperature response5–30 sDepends on airflow and thermal coupling
Long-term driftLess than 0.5%RH/year and 0.5°C/year typicalReference conditions

Keep the sensor away from heat sources and contaminants; avoid condensation.

Single-wire timing

Use the min/max windows from this revision

Scroll sideways to see all columns.

ParameterValueConditions / notes
Host start LOW18–30 ms20 ms typical
Host release interval10–35 µs13 µs typical
Sensor response LOW78–88 µs83 µs typical
Sensor response HIGH80–92 µs87 µs typical
Each bit LOW50–58 µs54 µs typical
Zero-bit HIGH23–27 µs24 µs typical
One-bit HIGH68–74 µs71 µs typical
Release after frame52–56 µs LOWThen sensor releases SDA

Use bounded receive timeouts. Interrupt latency must not obscure the short pulse windows.

Five-byte measurement frame

40 bits · MSB first · DHT11 format

Scroll sideways to see all columns.

ParameterValueConditions / notes
Byte 0Humidity integer52 decimal for 52.x%RH
Byte 1Humidity decimal portionFollow this device revision; do not combine as an AM2302 16-bit value
Byte 2Temperature integer magnitude25 decimal for +25.x°C
Byte 3Sign and temperature decimal portionBit 7 selects negative; lower bits carry fractional data
Byte 4Sum of bytes 0–3 modulo 256Reject the frame if the received check byte differs
Example frame34 00 19 00 4D hex52%RH, +25°C; 0x34+0x00+0x19+0x00=0x4D
Prior measurementReturned before a new conversionFor a fresh second result, keep the ≥2 s interval

Do not interpret DHT11 bytes with the AM2302 sign/magnitude 16-bit format.

Four leads, three connections

Front vent face toward you; leads down

Scroll sideways to see all columns.

ParameterValueConditions / notes
Pin 1 · VCC5 V in this exampleSensor and controller use the same rail
Pin 2 · SDAController bidirectional GPIO4.7 kΩ pullup to 5 V
Pin 3 · NCLeave openDo not ground this contact
Pin 4 · GNDCommon controller returnKeep motor currents away from the signal ground
Controller portOpen drain / switchable inputRelease the bus after the start pulse
3.3 V MCU with 5 V sensorCheck input tolerance or level-shiftDo not assume its input is 5 V tolerant
Communication topologyOne sensor per GPIONo device address is present in the DHT frame

The bare sensor and a breakout board can have different connector orders.

Enclosure and installation

Original package and footprint views

Scroll sideways to see all columns.

ParameterValueConditions / notes
Blue enclosure12.50×16.00×6.00 mmManufacturer drawing; nominal dimensions
Lead pitch2.54 mmFour straight leads; 7.62 mm outer span
Exposed lead length7.20±0.50 mmDrawing value
Lead section0.50×0.30 mm nominalCheck finished-hole allowance
Original footprint1.80 mm pads; 1.00 mm drillsUpright SIP-4; review assembly clearances
Air openingsKeep unobstructedEnclosures and absorbent materials can slow response
SMD packageNot shown for this sensorDo not substitute a generic IC package

The 3D view is an original nominal enclosure illustration; the KiCad file is a reviewed authored footprint.

Connections by function

Select a pin for its function, connection guidance and electrical notes.

Supply1 pin

Single-wire data1 pin

Not connected1 pin

Ground1 pin

Read the conditions with every value

Typical values describe stated test conditions. Absolute maximum ratings are stress limits, not operating targets.

Official PDF datasheet

Component view