PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation V1.0 comes as a ZIP archive of 21 files (4.1 MB, 9.2 MB unpacked) holding Proteus library files, simulation model DLLs, a Proteus simulation, an Arduino sketch and compiled HEX firmware.
- LIBProteus library
- DLLProteus model
- DSNProteus simulation
- INOArduino sketch
- HEXHEX firmware
Description
PT100-Cold-Chain-Logger-MAX31865-ESP32-Proteus-Simulation-v1.0.zip: the complete Proteus simulation project (an ESP32 DevKit V1, a MAX31865 with a PT100, a passive buzzer, an SSD1306 OLED, the Laptop and Mobile WiFi Monitors), the Arduino sketch ESP32_Cold_Chain.ino and its HEX, every LIB and DLL and a README.
File Structure
13.4 KB36.6 KB39.5 KB22.3 KB13.1 KB112.4 KB13.4 KB306.9 KB322 KB3.0 MB342.5 KB288.5 KB311 KB32.5 KB114.7 KB322 KB3.0 MB342.5 KB288.5 KB311 KB9.5 KBGallery12 images from the tutorialOpen the tutorial
The circuit, the board and the results as they appear in PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation. Open an image for its full size.












README
===============================================================================================================
PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation - Project V1.0
The Engineering Projects - www.TheEngineeringProjects.com
===============================================================================================================
IMPORTANT LINKS
The project tutorial (circuit, code, simulation results):
https://www.theengineeringprojects.com/2026/11/pt100-cold-chain-logger-max31865-esp32-proteus-simulation.html
The libraries this project is built from (each post has its own full download and tutorial):
ESP32 DevKit V1 board:
https://www.theengineeringprojects.com/2026/10/esp32-devkit-v1-library-for-proteus-v2-0.html
MAX31865 RTD sensor (PT100):
https://www.theengineeringprojects.com/2026/11/max31865-rtd-sensor-library-for-proteus.html
Passive buzzer:
https://www.theengineeringprojects.com/2026/11/passive-buzzer-library-for-proteus.html
Resistor:
https://www.theengineeringprojects.com/2026/11/resistor-library-for-proteus.html
OLED SSD1306:
https://www.theengineeringprojects.com/2026/10/oled-ssd1306-library-for-proteus-v1-0.html
Laptop WiFi Monitor:
https://www.theengineeringprojects.com/2026/10/laptop-wifi-monitor-library-for-proteus.html
Mobile WiFi Monitor:
https://www.theengineeringprojects.com/2026/10/mobile-wifi-monitor-library-for-proteus.html
Support our free work: https://www.theengineeringprojects.com/donate
FILE STRUCTURE
ESP32-Cold-Chain-TEP-v1.0/
|-- Proteus Library Files/
| |-- TEPESP32V1.LIB 36.6 KB a part of the project -> LIBRARY folder
| |-- TEPLAPTOP.LIB 39.5 KB a part of the project -> LIBRARY folder
| |-- TEPMAX31865.LIB 22.3 KB a part of the project -> LIBRARY folder
| |-- TEPMOBILE.LIB 13.1 KB a part of the project -> LIBRARY folder
| |-- TEPOLED12864.LIB 112.4 KB a part of the project -> LIBRARY folder
| |-- TEPPASSIVE.LIB 13.4 KB a part of the project -> LIBRARY folder
| |-- TEPRESISTOR.LIB 306.9 KB a part of the project -> LIBRARY folder
|-- Proteus Model Files/
| |-- TEPMAX31865.DLL 322.0 KB a model -> MODELS folder
| |-- TEPNET.DLL 3.01 MB a model -> MODELS folder
| |-- TEPOLED.DLL 342.5 KB a model -> MODELS folder
| |-- TEPPASSIVE.DLL 288.5 KB a model -> MODELS folder
| |-- TEPRESISTOR.DLL 311.0 KB a model -> MODELS folder
|-- Proteus Simulation/
| |-- ESP32_Cold_Chain.hex 114.7 KB the firmware U1 runs
| |-- ESP32-Cold-Chain.pdsprj 32.5 KB the project simulation
| |-- TEPMAX31865.DLL 322.0 KB copy of the model
| |-- TEPNET.DLL 3.01 MB copy of the model
| |-- TEPOLED.DLL 342.5 KB copy of the model
| |-- TEPPASSIVE.DLL 288.5 KB copy of the model
| |-- TEPRESISTOR.DLL 311.0 KB copy of the model
|-- Arduino Code/
| |-- ESP32_Cold_Chain/ESP32_Cold_Chain.ino 13.4 KB the sketch (source of the .hex)
|-- README.txt ~9.7 KB this file
Total: 9.19 MB (unzipped). The C++ source code of the models is not included.
WHAT IS IT?
A temperature logger for a vaccine or medicine fridge, which must stay between 2 and 8 C. An ESP32 reads a PT100
through a MAX31865 RTD converter, logs a sample every minute and keeps what a cold chain record needs: the minimum
and the maximum, the time above 8 C and below 2 C, and the mean kinetic temperature (MKT).
* U1 ESP32 DEVKIT V1 runs ESP32_Cold_Chain.hex on TEP-WiFi at 192.168.1.101.
* U2 the MAX31865 with a 3-wire PT100 (MAX31865TEP, PROFILE STEADY, TEMP 5 C - the fridge; WIRES 3, RREF 430; the
pop-up's chips: Room, Ice water, Boiling water, Oven, Probe open, Probe shorted): VIN on the VCC rail, CLK = D18,
SDO = D19 (MISO), SDI = D23 (MOSI), CS = D5, RDY = D4.
* BZ1 our passive buzzer from D33 through R1 100 ohm.
* OLED1 an SSD1306 128x64 OLED (OLED12864WHITEADVTEP, 0x3C) on I2C: SDA D21, SCL D22, VCC +3.3V.
* Laptop WiFi Monitor (PC1) and Mobile WiFi Monitor (MOB1) open http://192.168.1.101/.
What the sketch does:
the sensor CONFIG 0xD3 (VBIAS on, automatic conversions, 3-wire, fault clear, 50 Hz); on each DRDY the RTD
registers: code = (MSB:LSB) >> 1, R = code x 430 / 32768 ohm, the temperature from the PT100's
Callendar-Van Dusen curve; bit 0 set = a fault: the fault status (07h) is read and cleared; an open
probe reads 7FFFh, a shorted one 0000h
the log a sample every minute (TIME_SCALE 60: a simulated second is a minute of the log; 1 on a real
logger): the minimum, the maximum, the minutes above 8 C and below 2 C, the excursions, the last 120
samples for /log.csv and the OLED's trend
the MKT (dH / R) / -ln( mean of exp(-dH / (R T)) ) - 273.15, dH / R = 10,000 K (83.144 kJ/mol), T in kelvin
the alarms TOO WARM = above 8 C for 3 minutes; TOO COLD = below 2 C for 1 minute (freezing does its damage
fast); PROBE FAULT at once; each alarm latches and the buzzer sounds until ACK on the dashboard; the
record keeps every excursion
the record in range = fine to use; an excursion = keep the stock apart and check the maker's stability data
Its pages:
/ the dashboard with the links Refresh, ACK, NEW LOG and LOG.CSV
/log.csv the last 120 minutes /data JSON
Libraries: WiFi and WebServer (part of the ESP32 core), SPI, Wire, Adafruit SSD1306 and Adafruit GFX.
TEST STATUS
Tested in Proteus 8 Professional on Windows 11, the run that made the tutorial's screenshots (the log's clock):
- Start: "MAX31865 CONFIG 0xD1 (the fault clear clears itself) - found"; the fridge 4.96 - 5.02 C (101.94 ohm), MKT
5.03 C, in range.
- The power cut (the Room chip at about 08:16): 08:20 ALARM: TOO WARM - above 8 C for 3 minutes (19.0 C);
08:25 21.85 C, MKT 12.77 C; 08:35 22.05 C, MKT 16.50 C, 18 minutes above 8 C; ACK on the dashboard at 08:35.
- The ice (the Ice water chip): 08:41 ALARM: TOO COLD - below 2 C (1.5 C); 08:45 0.05 C, MKT 15.50 C, 21 minutes
above 8 C and 5 below 2 C.
- The probe open: 08:47 "PROBE FAULT: status 0x84 - open" and the alarm at once. /log.csv listed every minute.
- 60.3 s of simulation (47 minutes of the log) in 302 s.
INSTALLATION
1. Close Proteus. Extract the WHOLE zip file, for example to your Desktop.
2. Copy the files from "Proteus Library Files" into the LIBRARY folder of Proteus, for example
C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional\LIBRARY
3. Copy the files from "Proteus Model Files" into the MODELS folder (next to LIBRARY).
4. Start Proteus. Press P in the schematic and search for ESP32 DEVKIT V1 or MAX31865TEP to check that the parts are
there.
RUN THE SIMULATION
1. Open "Proteus Simulation\ESP32-Cold-Chain.pdsprj". Keep ESP32_Cold_Chain.hex and the DLL files beside it.
2. Press Play. The fridge is at 5 C; a simulated second is a minute of the log.
3. Click U2 for the sensor's pop-up and change the scene: Room (a power cut), Ice water, Probe open. Open the Laptop
or the Mobile WiFi Monitor (Go) for the dashboard: ACK silences an alarm, LOG.CSV shows the record.
PROPERTIES USED IN THIS PROJECT
U1 ESP32 DEVKIT V1 PROGRAM=ESP32_Cold_Chain.hex
U2 MAX31865TEP PROFILE=STEADY, TEMP=5, WIRES=3, RREF=430
R1 100; BZ1 BUZZERPASSIVETEP; OLED1 OLED12864WHITEADVTEP; PC1, MOB1 HOMEPAGE=http://192.168.1.101/
TROUBLESHOOTING
* "CONFIG 0x0 - not found?": SCK / MISO / MOSI / CS on D18 / D19 / D23 / D5, VIN on the VCC rail; the MAX31865 needs
SPI mode 1 or 3.
* PROBE FAULT: the probe is open or shorted (the pop-up's chips) - or a wiring fault on a real probe.
* The temperature reads about 2 C high: a 2-wire probe adds its leads' resistance - use 3 or 4 wires.
* The OLED stays dark: SDA / SCL on D21 / D22, VCC on +3.3V.
LICENCES
* The project, the sketch, the parts (LIB files) and the models (DLL files) are made by The Engineering Projects
and are free for learning and for your own projects. The models use only standard Windows libraries.
The C++ source code of the models is not included; the source code is not included for any model.
* The .hex file is built with the TEP Boards for Proteus and the Adafruit SSD1306 / GFX libraries.
* The limits and the alarm delays are typical values for learning; a real cold chain follows its own procedures.
* Proteus is a product of Labcenter Electronics and is not included. ESP32 is a product of Espressif Systems;
MAX31865 of Analog Devices (Maxim Integrated). This project is not made or endorsed by them.
VERSION
V1.0 - the first release of the project.
===============================================================================================================Development1 release
-
V1.0PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation V1.0this page
V1.0 is the only release in the Download Center so far. When a newer version is published, it appears above with its own download page.
Installation8 steps
From the download to a working project, in order. The steps follow what the package contains.
You will need
- Proteus Design SuiteProteus 8 or newer (Labcenter), on Windows
- Arduino IDE1.8 or 2.x, with the board of the tutorial chosen under Tools → Board
- Any archive toolWindows, macOS and Linux extract ZIP files on their own
Steps
- 1
Extract the archive
Right-click 08f457450a524182ae70b7cdf2851b62.zip and choose Extract All (or open it with 7-Zip or WinRAR) into a folder you can find again. Keep its folder structure (ESP32-Cold-Chain-TEP-v1.0) as it is.
- 2
Copy the library files into Proteus
Move TEPESP32V1.LIB, TEPLAPTOP.LIB and TEPMAX31865.LIB and 4 more and the files into the LIBRARY folder of your Proteus installation: C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional\LIBRARY for Proteus 8, or the matching Proteus 7 folder. Older versions keep it under ProgramData\Labcenter Electronics. If Proteus is open, close it first.
- 3
Add the simulation model
Copy TEPMAX31865.DLL, TEPNET.DLL and TEPOLED.DLL and 2 more into the MODELS folder next to LIBRARY, so the component can run, not only be drawn.
- 4
Restart Proteus and place the component
Start Proteus, open a schematic, press P (Pick Devices) and search for the component by the name used in the tutorial. It appears with its pins ready to wire.
- 5
Open the sketch in the Arduino IDE
Open ESP32_Cold_Chain.ino, select your board and port under Tools, then Verify. Sketch → Export Compiled Binary writes the HEX file a simulation needs.
- 6
Load the HEX file
In Proteus double-click the microcontroller, set Program File to ESP32_Cold_Chain.hex and run the simulation. For real hardware, flash the same file with your programmer.
- 7
Open the example simulation
Open ESP32-Cold-Chain.pdsprj in Proteus to see the wiring exactly as in the tutorial. Check the controller's Program File path, then press Play.
- 8
Follow the tutorial
PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation explains every connection and setting in order; keep it open beside the files while you build.
FAQs9 questionsContact TEP
How do I download PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation V1.0?
Wait for the 30-second guest countdown on this page, then press the download button; the file comes straight from our storage. Members who are logged in skip the wait. If the browser opens the file instead of saving it, use its Save as option. The download link is made for you when the countdown ends and works for 15 minutes; a saved or shared link stops working, so share this page instead.
What is inside the archive?
PT100 Cold Chain Logger with MAX31865 and ESP32 - Proteus Simulation V1.0 comes as a ZIP archive of 21 files (4.1 MB, 9.2 MB unpacked) holding Proteus library files, simulation model DLLs, a Proteus simulation, an Arduino sketch and compiled HEX firmware. Open the File Structure tab for the full list of 21 files.
What should I do if the download does not start?
Check the browser's download list first; an ad blocker or a company firewall can also hold it back, so try another browser or network. If the file arrives incomplete, download it again. For an installation problem, read the Install tab or tell us in the comments with your software version and the exact error message.
Is this file free?
Yes. Every file in the TEP Download Center is free for learning, personal and student projects. If you share it, link back to this page or the tutorial so others find the latest version.
How do I check that the file arrived complete?
Compare its SHA-256 with the one on this page, 170c716d3402a5a65d731ac696ebe83cdb6b9322b57142e2580b9a2b120f11a7. In PowerShell run Get-FileHash "08f457450a524182ae70b7cdf2851b62.zip"; on macOS or Linux run shasum -a 256 "08f457450a524182ae70b7cdf2851b62.zip". The same value means the file is exactly the one in our storage; a different one means the download broke off, so download it again.
Do I need WinRAR to open the ZIP file?
No. Windows, macOS and Linux open ZIP archives on their own (Extract All, or double-click). WinRAR and 7-Zip work too. Extract the whole archive before using the files.
Where do I put the LIB and IDX files?
Both files go into the LIBRARY folder of your Proteus installation (Proteus 8: C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional\LIBRARY; Proteus 7 has the same folder under its own name). Restart Proteus afterwards and search for the component with P.
Which Proteus version does the library need?
The tutorial names the Proteus version the library was made and tested with. Most TEP libraries work in Proteus 7 and Proteus 8; if the component does not appear after a restart, check that both the LIB and the IDX file were copied and that Proteus was fully closed while copying.
How do I get the HEX file into the simulation?
Compile the sketch in the Arduino IDE (Sketch → Export Compiled Binary gives you the HEX next to the sketch), then in Proteus double-click the board, set Program File to that HEX and run.
Members skip the wait. Log in or join TEP.
- 0Total downloads
- 4%Popularity
- ESP32 ProjectsCategory
- 0Comments
- ssyedzainnasirUploaded by
- 29 Nov 2026Uploaded at
170c716d3402a5a65d731ac696ebe83cdb6b9322b57142e2580b9a2b120f11a7






















Comments
0