TEP DOWNLOAD CENTER

Project Files of PZEM-017 DC Energy Meter Library for Proteus Simulation

Libraries Code Projects Simulation
tep://download-terminal 50c3159fe73f4281b9e589f777b0a318.zip ZIP archiveV1.0Verified0 downloadsFree
PZEM-017 DC Energy Meter Library for Proteus Simulation: an Arduino UNO V4.0, a MAX485 module, the PZEM-017, a shunt, a load and a lead-acid battery
Proteus library · File 1 of 1

PZEM-017 DC Energy Meter Library for Proteus V1.0

PZEM-017 DC Energy Meter Library for Proteus V1.0 comes as a ZIP archive of 13 files (1.5 MB, 3.3 MB unpacked) holding Proteus library files, simulation model DLLs, a Proteus simulation, an Arduino sketch and compiled HEX firmware.

  • LIBProteus library
  • DLLProteus model
  • DSNProteus simulation
  • INOArduino sketch
  • HEXHEX firmware

Description

PZEM-017-DC-Energy-Meter-Library-for-Proteus-v1.0.zip with the PZEM-017 energy meter for Proteus simulation (TEPPZEM017.LIB and TEPPZEM017.DLL), our 12V lead-acid battery, our Arduino UNO V4.0, the A3 demo with its sketch and a README.

Read PZEM-017 DC Energy Meter Library for Proteus Simulation

File Structure

50c3159fe73f4281b9e589f777b0a318.zip13 files · 5 folders · 3.3 MB unpacked
PZEM-017-DC-Energy-Meter-TEP-v1.0/13 files · 3.3 MB
Arduino Code/1 file · 5.7 KB
Pzem017_Demo/1 file · 5.7 KB
INO Pzem017_Demo.inoArduino sketch 5.7 KB
Proteus Library Files/3 files · 235.4 KB
LIB ArduinoV4TEP.LIBProteus library 201.9 KB
LIB TEPLEADACID.LIBProteus library 16.2 KB
LIB TEPPZEM017.LIBProteus library 17.3 KB
Proteus Model Files/3 files · 1.5 MB
DLL TEPARDUINO.DLLSimulation model 883.5 KB
DLL TEPLEADACID.DLLSimulation model 325 KB
DLL TEPPZEM017.DLLSimulation model 315 KB
Proteus Simulation/5 files · 1.5 MB
DSN PZEM-017-Energy-Meter-RS485-Battery-ArduinoUnoV4.pdsprjProteus simulation 24.1 KB
HEX Pzem017_Demo.hexCompiled HEX file 22.3 KB
DLL TEPARDUINO.DLLSimulation model 883.5 KB
DLL TEPLEADACID.DLLSimulation model 325 KB
DLL TEPPZEM017.DLLSimulation model 315 KB
TXT README.txtText file 17.6 KB

README

README.txt 302 lines
PZEM-017 DC ENERGY METER LIBRARY FOR PROTEUS SIMULATION - V1.0 (RS485, Modbus-RTU, a shunt, a pop-up)
Designed by The Engineering Projects
www.TheEngineeringProjects.com

IMPORTANT LINKS
Article (read it first - pictures, step by step, every feature explained):
  https://www.theengineeringprojects.com/2026/11/pzem-017-dc-energy-meter-library-for-proteus.html
Report a bug or suggest a feature (our forum):
  https://www.theengineeringprojects.com/forum/category/motor-driver-proteus-library
The demo runs on our Arduino UNO V4.0 (included) - working LEDs, RESET and a
built-in serial monitor, no Virtual Terminal to wire - its own article:
  https://www.theengineeringprojects.com/2026/10/arduino-uno-library-for-proteus-v40.html
The demo talks to the meter through our MAX485 RS-485 module library (installed from its own package - not in this zip):
  https://www.theengineeringprojects.com/2026/10/max485-rs485-module-library-for-proteus-v1-0.html
The demo's battery is our 12V Lead-Acid Battery library (its LIB and DLL are in this zip; its own article):
  https://www.theengineeringprojects.com/2026/11/12v-lead-acid-battery-library-for-proteus.html
The demo sketch needs the AltSoftSerial 1.4 library (MIT) by Paul Stoffregen - install it with the Library Manager:
  https://github.com/PaulStoffregen/AltSoftSerial
Support us (the libraries are free):
  https://www.theengineeringprojects.com/donate

FILE STRUCTURE
PZEM-017-DC-Energy-Meter-TEP-v1.0/
|-- Proteus Library Files/
|   |-- ArduinoV4TEP.LIB                              201.9 KB   TEP Arduino boards V4.0 (UNO) -> LIBRARY
|   |-- TEPLEADACID.LIB                                16.2 KB   a part the demo uses -> LIBRARY folder
|   |-- TEPPZEM017.LIB                                 17.3 KB   the library -> LIBRARY folder
|-- Proteus Model Files/
|   |-- TEPARDUINO.DLL                                883.5 KB   the Arduino board model -> MODELS folder
|   |-- TEPLEADACID.DLL                               325.0 KB   its model -> MODELS folder
|   |-- TEPPZEM017.DLL                                315.0 KB   the model -> MODELS folder
|-- Proteus Simulation/
|   |-- Pzem017_Demo.hex                               22.3 KB   the demo firmware
|   |-- PZEM-017-Energy-Meter-RS485-Battery-ArduinoUnoV4.pdsprj   24.1 KB   the demo project
|   |-- TEPARDUINO.DLL                                883.5 KB   copy of the board model
|   |-- TEPLEADACID.DLL                               325.0 KB   copy of its model
|   |-- TEPPZEM017.DLL                                315.0 KB   copy of the model
|-- Arduino Code/
|   |-- Pzem017_Demo/Pzem017_Demo.ino                   5.7 KB   the demo sketch (source of the .hex)
|-- README.txt                                        ~18.7 KB   this file
Total: 3.27 MB (unzipped). The C++ source code of the models is not included.

WHAT IS IT?
The PZEM-017 DC communication module - a DC energy meter with an external shunt that is read over
RS485 with Modbus-RTU -
drawn compact from above (the dark ribbed case with its two green terminal blocks; our own drawing,
no maker's mark). The real
case is 90 x 60.5 mm, larger than an Arduino UNO; the symbol is drawn at 0.7 of that. The figures
are from the maker's
specification of the module:
  * It measures the voltage on V+ / V- (0.05 to 300 V, in steps of 0.01 V) and the current through a
    shunt in the NEGATIVE
    lead (from 0.02 A, in steps of 0.01 A; a 75 mV shunt of 50, 100, 200 or 300 A), works out the
    power (0.1 W) and counts
    the energy (1 Wh, up to 9999 kWh). SH- is the shunt's sense wire on the supply's side, SH+ the
    one on the load's side.
  * Above 7 V the module runs from the supply it measures (ours: it takes 10 mA). Under 7 V it needs
    5 V on its USB port:
    the USB property.
  * A high and a low voltage alarm, 300 V and 7 V at the start; the master can change both.
  * The RS485 side: 5V, B, A, GND. It needs its own 5 V. 9600 baud, 8 data bits, 2 stop bits, no
    parity.
  * Modbus-RTU: 0x04 reads the eight measurement registers, 0x03 the four parameter registers, 0x06
    writes one of them,
    0x42 resets the energy; the address 1 to 247, the general address 0xF8, the broadcast address 0;
    CRC-16, low byte
    first; exceptions 1 (function), 2 (register), 3 (value). The meter answers 10 ms after the
    request has ended.
  * On the sheet three lamps work at Run (PWR, TX, RX - our additions) and the label plate shows the
    volts, the amps, the
    watts and the watt-hours. Click it at Run for the pop-up: the circuit with the shunt, the last
    Modbus frames byte by
    byte with their meaning, eight live values; graphs, an event log and a check page.
The body is drawn as on the real part and to true scale against our Arduino.
The TEP signature and the pop-up are TEP additions.

ONE DEVICE (search "PZEM" or "ENERGY METER" in Pick Devices):
  PZEM017TEP  "PZEM-017 DC Energy Meter with RS485 Modbus V1.0" in TEPPZEM017.LIB (Electromechanical
  > Energy Meters),
              prefix EM, model TEPPZEM017.DLL (mixed: analog and digital). Eight pins: on the left
              V+, V- (the supply to
              be measured), SH-, SH+ (the shunt's sense wires); on the right 5V, B, A, GND (the
              RS485 side).

THE POP-UP
Click the part at Run. Tabs:
    Meter      chips: the energy counter's clock (x 1, x 60, x 3600) and Reset energy. The circuit -
    the supply, the load
               and the shunt in the negative lead, with the volts, the shunt's millivolts and the
               amps; the last six
               Modbus frames on the pair, the newest first: when, request or answer, what it means,
               and every byte;
               eight live values: the voltage, the current, the power, the energy, the alarm and its
               two thresholds, the
               millivolts across the shunt and its resistance, the requests and answers, the CRC
               errors and exceptions.
    Graphs     the live values over the last 2, 6 or 15 s. Live / Freeze.
    Event log  every change and warning; filters All / Changes / Warnings, Pause, Clear
    Check      what the part is doing and what to look at, each with a verdict (green = fine, amber
    = check, red = wrong)
    Settings   theme, text size, open at Run, window size
    Help       report a bug, suggest a feature, article, updates, donate, forum; Copy diagnostics
    for a bug report

TEST STATUS
V1.0: verified in Proteus 8.5 on 16 Nov 2026 (the demo project as shipped: an A3 sheet, an Arduino UNO V4.0).
What the runs showed (the model's own numbers and the sketch's monitor):
The demo as shipped (Pzem017_Demo; EM1 ADDRESS 1, RANGE 50, SPEED 3600; BAT1 our 12 V 7.2 Ah
lead-acid battery, SOC
60, SPEED 3600; R1 6 ohm, the load; R2 0.0015 ohm, the 50 A / 75 mV shunt in the negative lead; U1
our MAX485 module),
one run (emfinal3), the model's pauses:
  * At the start the meter is powered from the measured supply (12.36 V). The sketch's two writes:
    at 233.1 ms
    register 3 = 1 (the shunt 50 A / 75 mV, 1.50 mohm), frame 01 06 00 03 00 01 B8 0A, echoed; at
    269.7 ms register 1
    = 1180 (the low voltage alarm 11.80 V), frame 01 06 00 01 04 9C DA A3, echoed.
  * 0.4 s, MEASURING: 12.16 V, 2.03 A (3.04 mV across the shunt), 24.7 W, 7 Wh. The first read: the
    request 01 04 00
    00 00 08 F1 CC complete at 0.306 s, the answer at 0.316 s: 01 04 10 04 C0 00 CB 00 F7 00 00 00
    07 00 00 00 00 00
    00 E3 82 (1216, 203, 247, 7; no alarm). 3 requests, 3 answers.
  * 0.85 s: 11.94 V, 1.99 A (2.98 mV), 23.8 W, 19 Wh. The request at 0.807 s, the answer at 0.817 s:
    01 04 10 04 AA 00
    C7 00 EE 00 00 00 13 00 00 00 00 00 00 36 3C. On the sheet the plate shows 11.94 V 1.99 A and
    23.8 W 19 Wh, the
    PWR lamp is lit. The battery's pop-up: 1.99 A out, 11.90 V at the terminals, 29 % left, 48 min
    to empty. The
    MAX485 module's pop-up: 8 frames (4 sent, 4 received), 0 CRC errors, the same bytes.
  * LOW VOLTAGE ALARM at 1.100 s: 11.79 V is under the threshold of 11.80 V.
  * 1.35 s: 11.67 V, 1.94 A (2.92 mV), 22.6 W, 31 Wh; the answer at 1.316 s carries the alarm in
    register 7: 01 04 10
    04 8F 00 C2 00 E2 00 00 00 1F 00 00 00 00 FF FF 2D C2. 5 requests, 5 answers.
  * 1.6 s: 11.48 V, 1.91 A (2.87 mV), 21.9 W, 35 Wh.
  * In all: the voltage between 11.48 V and 12.27 V, the most current 2.04 A, the most power 25.0 W,
    35 Wh counted; 5
    requests, 5 answers, 2 writes; 0 frames with a wrong CRC, 0 exceptions.
  * The monitor: Shunt 50 A: set; Low voltage alarm 11.80 V: set; then 12.16 V 2.03 A 24.7 W 7 Wh
    ok; 11.94 V 1.99 A
    23.8 W 19 Wh ok; 11.67 V 1.94 A 22.6 W 31 Wh LOW VOLTAGE ALARM. 84 s for the 1.6 s of the run.
A second run with the meter's ADDRESS 5 (emaddr2), the sketch still asking slave 1: at 0.9 s the
meter has heard three
requests (0.233 s, 0.446 s, 0.659 s), each marked "for slave 1: not this meter (address 5)"; 0
requests taken, 0
answers; it goes on measuring (11.94 V, 1.99 A, 23.8 W, 19 Wh) and the low alarm stays at 7.00 V.

INSTALLATION (about 2 minutes)
1. Close Proteus. Extract the WHOLE ZIP to a normal folder (e.g. Desktop).
2. Copy everything in "Proteus Library Files" (TEPPZEM017.LIB, TEPLEADACID.LIB and our Arduino
library V4.0, ArduinoV4TEP.LIB, with the ARDUINO UNO V4.0 used by the demo) to the LIBRARY folder of
Proteus, for example:
     C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional\LIBRARY
   (use the folder that already holds Proteus's own .LIB files).
3. Copy TEPPZEM017.DLL, TEPLEADACID.DLL and TEPARDUINO.DLL from "Proteus Model Files" to the MODELS
folder (...\Proteus 8 Professional\MODELS).
4. Delete TEPPZEM017.IDX from the LIBRARY folder if it is there (Proteus makes a new index).
5. Start Proteus. In Pick Devices (P) search "PZEM".

RUN THE DEMO
"Proteus Simulation\PZEM-017-Energy-Meter-RS485-Battery-ArduinoUnoV4.pdsprj" (an A3 sheet) - keep
the .hex file and the DLLs beside the project.
  A battery energy monitor over RS485:
  ARD1:   Arduino UNO V4.0 running Pzem017_Demo.hex, its serial monitor built in (window "TEP
  Arduino UNO - ARD1").
  U1:     our MAX485 RS-485 module (its pop-up version): RO to D8, DI to D9, DE and RE to D2; A and
  B to the meter.
  EM1:    the meter: address 1, RANGE 50, SPEED 3600; V+ on the battery's +, V- and SH- on its -
  (ground), SH+ on
          the load's side of the shunt; 5V and GND on the supply rails.
  BAT1:   our 12 V 7.2 Ah lead-acid battery, SOC 60 %, SPEED 3600 (an hour each simulated second), -
  on ground.
  R1:     6 ohm, the load, from the battery's + to the shunt.
  R2:     0.0015 ohm, the 50 A / 75 mV shunt, from the load to the battery's -: in the negative
  lead.
          The sketch is a Modbus master written out by hand: it tells the meter the shunt's size
          (register 3 = 1) and
          sets the low voltage alarm to 11.80 V (register 1 = 1180), then reads the eight
          measurement registers twice a
          second and prints the volts, amps, watts, watt-hours and the alarm; the UNO's LED lights
          with the alarm.
Closed the monitor? Click the UNO's USB port.

WIRING (the same in Proteus and on a real board)
  The shunt belongs in the NEGATIVE lead, between the supply's - and the load's -. V+ to the
  supply's +; V- and SH- to
  the shunt's end on the supply's side; SH+ to its end on the load's side. A to A and B to B of the
  RS485 adapter or MAX485
  module; 5V and GND of the RS485 side to a 5 V supply. In the simulation both sides share the
  ground; the real module
  isolates the RS485 side with optocouplers.
REAL HARDWARE:
 * Tell the meter the shunt you fitted (register 3: 0 = 100 A, 1 = 50 A, 2 = 200 A, 3 = 300 A), or
   every current is
   wrong by the same factor. The real module remembers its parameters; our model starts from the
   properties each run.
 * The measured voltage can be deadly: up to 300 V DC. Fuse the V+ wire, and never open the wiring
   under voltage.
 * Never feed the module's USB port from a PC when it measures: the maker warns that this can damage
   the PC.
 * On a long RS485 line add the 120 ohm terminators at both ends and keep A and B as a twisted pair.
 * The energy counter is in whole watt-hours: at a few watts it moves slowly. SPEED only makes the
   demo's clock run fast.

THE DEMO SKETCH ON THE SERIAL MONITOR (Pzem017_Demo V1.0, 9600 baud)
The sketch reports every 500 ms. Type a command:
  reset      the meter's energy counter back to 0       rate 1000      report every 1000 ms
  help
EXPECTED MONITOR OUTPUT
  Battery energy monitor - The Engineering Projects
  Shunt 50 A: set
  Low voltage alarm 11.80 V: set
  Commands: reset | rate 500 | help
  12.16 V  2.03 A  24.7 W  7 Wh  ok
  11.94 V  1.99 A  23.8 W  19 Wh  ok
  11.67 V  1.94 A  22.6 W  31 Wh  LOW VOLTAGE ALARM

PROPERTIES (double-click the part > Edit Properties)
  Modbus address (ADDRESS)             1 - 247 (1); register 2 changes it at Run
  The shunt (RANGE)                    50, 100, 200 or 300 A, a 75 mV shunt (100); register 3
  changes it at Run
  USB supply (USB)                     NO, or YES for a test voltage under 7 V (NO)
  Clock (SPEED)                        of the energy counter: 1 real time, 3600 an hour each
  simulated second, 1 - 7200 (1)
Every run starts again from the properties.

LINKS.INI (OPTIONAL)
The Help page cards of the pop-up open web pages. To point them somewhere else without a new DLL,
put a text file named links.ini next to TEPPZEM017.DLL with lines KEY=URL, for example:
  ARTICLE=https://www.theengineeringprojects.com/...
Keys: WEBSITE, FORUM, BUG_REPORT, FEATURE_REQUEST, ARTICLE, USER_GUIDE,
UPDATE_CHECK, DONATE. Only http:// and https:// links are used; lines starting
with # are comments.

TROUBLESHOOTING
* No answer from the meter: A and B are swapped; DE / RE is not switched (HIGH to send, LOW to
  listen); the address is not
  the meter's; or the RS485 side has no 5 V. The pop-up's frame list shows what arrived.
* NO SUPPLY on the plate: under 7 V on V+ / V-. Set USB to YES for a low test voltage.
* The current reads 0: the shunt is in the wrong lead or SH- / SH+ are not on the shunt's two ends;
  under 0.02 A the
  meter shows 0.
* The current is wrong by a factor of 2: register 3 does not match the shunt (the meter starts with
  100 A).
* The power and energy look split in two: each is two registers, the LOW word first.
* CRC errors in the pop-up: the master sent the CRC's high byte first. Modbus sends the low byte
  first.
* The part is not simulated: TEPPZEM017.DLL is missing from MODELS and from the project folder.
* The part is not simulated: TEPPZEM017.DLL is missing from MODELS and from the project folder. No
  UNO / no monitor window: TEPARDUINO.DLL is missing, or click the UNO's USB port.

BUG REPORTS AND FEATURE REQUESTS
Please post them in our forum with a screenshot, the Serial Monitor text, the
simulation log and the pop-up's Copy diagnostics text:
  https://www.theengineeringprojects.com/forum/category/motor-driver-proteus-library

SUPPORT US
This library is free. If it saves you time, please support our work:
  https://www.theengineeringprojects.com/donate

WEBSITE
  https://www.theengineeringprojects.com/

LICENCES AND THIRD-PARTY NOTES
* The model (TEPPZEM017.DLL), the symbols and artwork, the other parts of ours in the demo and the
  Arduino Library V4.0 (ArduinoV4TEP.LIB / TEPARDUINO.DLL, with its built-in TEP Serial Monitor
  Advance) are made by The Engineering Projects. The models use only standard Windows libraries; no
  Visual C++ redistributable is needed.
  The C++ source code is not included.
* Arduino UNO V4.0 (ArduinoV4TEP.LIB / TEPARDUINO.DLL, our Arduino Library V4.0 - its
  microcontroller is Proteus's own AVR model): The Engineering Projects,
  https://www.theengineeringprojects.com/2026/10/arduino-uno-library-for-proteus-v40.html
* The .hex file is built from the demo sketch and the Arduino AVR core 1.8.6, which includes
  LGPL-licensed code; its source code is available at
  https://github.com/arduino/ArduinoCore-avr/tree/1.8.6
* Proteus is a product of Labcenter Electronics and is not included. Arduino is a trademark of Arduino SA.
  This library is not made or endorsed by Arduino or Labcenter.

REBUILDING THE FIRMWARE (OPTIONAL)
The HEX file is supplied; Arduino IDE is not needed to run the demo. To edit the sketch, open
Arduino Code\Pzem017_Demo\Pzem017_Demo.ino, select Arduino Uno and use Sketch > Export Compiled
Binary. Replace the simulation's .hex with the exported HEX. The sketch needs 8,128 bytes of flash
and 479 bytes of RAM.

MODEL SCOPE AND LIMITS
Modelled: the voltage and current measurement from ten means a second, the ranges and steps of the
specification, the
power and the energy counter (SPEED), both alarms and their thresholds; the supply from the measured
voltage above 7 V
(10 mA - ours) or from USB; the RS485 pair, 9600 baud with two stop bits; Modbus-RTU with the
functions 0x03, 0x04, 0x06,
0x42 and 0x41 (answered, nothing to calibrate), the addresses, the CRC and the exceptions; the
answer 10 ms after the
request (ours). Not modelled: the 1 % accuracy band, the isolation between the two sides (they share
the ground here), the
storing of the parameters when the power is off, the PZEM-003 with its built-in 10 A shunt.

VERSION
TEP PZEM-017 DC Energy Meter library V1.0 (Nov 2026). Device PZEM017TEP (TEPPZEM017.LIB /
TEPPZEM017.DLL). Demo sketch Pzem017_Demo V1.0 (a Modbus master by hand, AltSoftSerial). The demo
also uses our 12V Lead-Acid Battery (TEPLEADACID: LEADACIDBAT12V7TEP), shipped in this package, and
our MAX485 RS-485 module (installed from its own package). Demo board: ARDUINO UNO V4.0 (TEP Arduino
Library V4.0) with its built-in serial monitor.
Advertisement

Development1 release

  1. V1.0PZEM-017 DC Energy Meter Library for Proteus V1.0this page

    V1.0 is the only release in the Download Center so far. When a newer version is published, it appears above with its own download page.

Installation8 steps

From the download to a working project, in order. The steps follow what the package contains.

You will need

  • Proteus Design SuiteProteus 8 or newer (Labcenter), on Windows
  • Arduino IDE1.8 or 2.x, with the board of the tutorial chosen under Tools → Board
  • Any archive toolWindows, macOS and Linux extract ZIP files on their own

Steps

  1. 1

    Extract the archive

    Right-click 50c3159fe73f4281b9e589f777b0a318.zip and choose Extract All (or open it with 7-Zip or WinRAR) into a folder you can find again. Keep its folder structure (PZEM-017-DC-Energy-Meter-TEP-v1.0) as it is.

  2. 2

    Copy the library files into Proteus

    Move ArduinoV4TEP.LIB, TEPLEADACID.LIB and TEPPZEM017.LIB and the files into the LIBRARY folder of your Proteus installation: C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional\LIBRARY for Proteus 8, or the matching Proteus 7 folder. Older versions keep it under ProgramData\Labcenter Electronics. If Proteus is open, close it first.

  3. 3

    Add the simulation model

    Copy TEPARDUINO.DLL, TEPLEADACID.DLL and TEPPZEM017.DLL into the MODELS folder next to LIBRARY, so the component can run, not only be drawn.

  4. 4

    Restart Proteus and place the component

    Start Proteus, open a schematic, press P (Pick Devices) and search for the component by the name used in the tutorial. It appears with its pins ready to wire.

  5. 5

    Open the sketch in the Arduino IDE

    Open Pzem017_Demo.ino, select your board and port under Tools, then Verify. Sketch → Export Compiled Binary writes the HEX file a simulation needs.

  6. 6

    Load the HEX file

    In Proteus double-click the microcontroller, set Program File to Pzem017_Demo.hex and run the simulation. For real hardware, flash the same file with your programmer.

  7. 7

    Open the example simulation

    Open PZEM-017-Energy-Meter-RS485-Battery-ArduinoUnoV4.pdsprj in Proteus to see the wiring exactly as in the tutorial. Check the controller's Program File path, then press Play.

  8. 8

    Follow the tutorial

    PZEM-017 DC Energy Meter Library for Proteus Simulation explains every connection and setting in order; keep it open beside the files while you build.

How to add a library in Proteus 8

FAQs9 questionsContact TEP

How do I download PZEM-017 DC Energy Meter Library for Proteus V1.0?

Wait for the 30-second guest countdown on this page, then press the download button; the file comes straight from our storage. Members who are logged in skip the wait. If the browser opens the file instead of saving it, use its Save as option. The download link is made for you when the countdown ends and works for 15 minutes; a saved or shared link stops working, so share this page instead.

What is inside the archive?

PZEM-017 DC Energy Meter Library for Proteus V1.0 comes as a ZIP archive of 13 files (1.5 MB, 3.3 MB unpacked) holding Proteus library files, simulation model DLLs, a Proteus simulation, an Arduino sketch and compiled HEX firmware. Open the File Structure tab for the full list of 13 files.

What should I do if the download does not start?

Check the browser's download list first; an ad blocker or a company firewall can also hold it back, so try another browser or network. If the file arrives incomplete, download it again. For an installation problem, read the Install tab or tell us in the comments with your software version and the exact error message.

Is this file free?

Yes. Every file in the TEP Download Center is free for learning, personal and student projects. If you share it, link back to this page or the tutorial so others find the latest version.

How do I check that the file arrived complete?

Compare its SHA-256 with the one on this page, 365ef583209a9d81a4f594517ea895213d6f9b704554855d7b48c48dad38b767. In PowerShell run Get-FileHash "50c3159fe73f4281b9e589f777b0a318.zip"; on macOS or Linux run shasum -a 256 "50c3159fe73f4281b9e589f777b0a318.zip". The same value means the file is exactly the one in our storage; a different one means the download broke off, so download it again.

Do I need WinRAR to open the ZIP file?

No. Windows, macOS and Linux open ZIP archives on their own (Extract All, or double-click). WinRAR and 7-Zip work too. Extract the whole archive before using the files.

Where do I put the LIB and IDX files?

Both files go into the LIBRARY folder of your Proteus installation (Proteus 8: C:\Program Files (x86)\Labcenter Electronics\Proteus 8 Professional\LIBRARY; Proteus 7 has the same folder under its own name). Restart Proteus afterwards and search for the component with P.

Which Proteus version does the library need?

The tutorial names the Proteus version the library was made and tested with. Most TEP libraries work in Proteus 7 and Proteus 8; if the component does not appear after a restart, check that both the LIB and the IDX file were copied and that Proteus was fully closed while copying.

How do I get the HEX file into the simulation?

Compile the sketch in the Arduino IDE (Sketch → Export Compiled Binary gives you the HEX next to the sketch), then in Proteus double-click the board, set Program File to that HEX and run.

preparing · 50c3159fe73f4281b9e589f777b0a318.zip
Rating
Your download will be ready shortly
Preparing your download…

Members skip the wait. Log in or join TEP.

  • 0Total downloads
  • 4%Popularity
  • ProteusCategory
  • 0Comments
  • ssyedzainnasirUploaded by
  • 16 Nov 2026Uploaded at
Last 14 days0 downloads
SHA-256 365ef583209a9d81a4f594517ea895213d6f9b704554855d7b48c48dad38b767
DocumentationPZEM-017 DC Energy Meter Library for Proteus Simulation
Need help with this file? Bug report Ask a question Download problemsGet updates
Advertisement

Comments

0

Join the conversation

Start the conversationAsk a question or share how you used this download.